Front Panel Control
4-26
EN/LZT 790 0023/1 R16A
FPGA Temperature
FPGA Warning Temperature
The temperature in degrees centigrade of the host FPGA at which the
unit issues a warning.
FPGA Over Temperature
The temperature in degrees centigrade of the host FPGA at which the
unit issues a critical alarm.
FPGA Temperature
The current temperature in degrees centigrade of the host FPGA.
PHY0 Temperature
PHY0 Warning Temperature
The temperature in degrees centigrade of the Ethernet PHY0 at which
the unit issues a warning.
PHY0 Over Temperature
The temperature in degrees centigrade of the Ethernet PHY0 at which
the unit issues a critical alarm.
PHY0 Temperature
The current temperature in degrees centigrade of Ethernet PHY0.
PHY1 Temperature
PHY1 Warning Temperature
The temperature in degrees centigrade of the Ethernet PHY1 at which
the unit issues a warning.
PHY1 Over Temperature
The temperature in degrees centigrade of the Ethernet PHY1 at which
the unit issues a critical alarm.
PHY1 Temperature
The current temperature in degrees centigrade of the Ethernet PHY1.
Mux SCR Source
Internal, Video. The source of the system clock reference used for
timing.
Status of Service
The Setmode state of the unit.
Change State
Changes the Setmode state of the unit. The available options depend
on the settings in Advanced/System/Base Unit/MGP Support/MGP
Mode.
IP Input system Compensation
0 – 5000 ms
What to Do on Reboot
Restore, Offline. Determines whether the streams remain offline after
reboot or their Setmode state is to be restored.
TS Source IP Redundancy
Non-Transparent, Transparent
BISS Mode
BISS Security option (Normal or Advanced)
BISS Injected ID (14 hex digits)
BISS injected ID used for transmitting the Encrypted Session Word
used for BISS-E encoding.
BISS Keys table
Table locations for BISS key storage and selection
UTC Time
The UTC time set on the unit.
UTC Date
The UTC date set on the unit.
SNTP Server
The IP address of a time server in the network.
Reflex Version
1
Selects the Reflex version to use for statistical multiplexing. Not
supported in the current release.
DPI TCP Port
The port for the SCTE104 Slice messages to be transmitted.
Alarm Status
The overall alarm status of the unit. The same as indicated by the light
pipe on the front panel.
Summary of Contents for AVP 1000 1RU
Page 10: ...Preliminary Pages x EN LZT 790 0023 1 R16A BLANK...
Page 42: ...Installing the Equipment 2 18 EN LZT 790 0023 1 R16A BLANK...
Page 176: ...Front Panel Control 4 60 EN LZT 790 0023 1 R16A BLANK...
Page 319: ...Web GUI Control EN LZT 790 0023 1 R16A 5 143 Figure 5 43Support Page Device Management Tab...
Page 320: ...Web GUI Control 5 144 EN LZT 790 0023 1 R16A BLANK...
Page 324: ...Advanced Video Processing and Networking 6 4 EN LZT 790 0023 1 R16A BLANK...
Page 374: ...Options Licensing and Upgrades 7 28 EN LZT 790 0023 1 R16A BLANK...
Page 396: ...Preventive Maintenance and Fault finding 8 22 EN LZT 790 0023 1 R16A BLANK...
Page 444: ...Technical Specification B 28 EN LZT 790 0023 1 R16A BLANK...
Page 446: ...Audio Coding C 2 EN LZT 790 0023 1 R16A BLANK...
Page 452: ...Differences For Contribution Encoder and Voyager II D 2 EN LZT 790 0023 1 R16A BLANK...
Page 456: ...Differences For Contribution Encoder and Voyager II D 6 EN LZT 790 0023 1 R16A BLANK...
Page 458: ...Alarm Lists E 2 EN LZT 790 0023 1 R16A BLANK...
Page 500: ...Alarm Lists E 44 EN LZT 790 0023 1 R16A BLANK...
Page 502: ...Logo Creator F 2 EN LZT 790 0023 1 R16A BLANK...
Page 508: ...Logo Creator F 8 EN LZT 790 0023 1 R16A BLANK...