Alarm Lists
E-6
EN/LZT 790 0023/1 R16A
Alarm
Description
Port Number
Alarm ID
Source
Severity
Over Temperature Warning
Failure to take action may cause
permanent damage to the unit.
Please check the fans are working
correctly, and that the ambient
temperature is not excessive.
0
00000442
Base Unit
minor
Over Temperature
Failure to take action may cause
permanent damage to the unit.
Please switch off and refer to
Customer Support.
0
00000443
Base Unit
critical
Power On Self Test Failure
At least one start-up test has failed.
Problems amy be experienced with
the normal operation of the unit.
0
00000444
Base Unit
minor
+12V A Failed
+12V A rail has failed. Please check
supply or contact Customer Support.
0
00000445
Base Unit
warning
+12V B Failed
+12V B rail has failed. Please check
supply or contact Customer Support.
0
00000446
Base Unit
warning
Real Time Clock
The Real-time clock has failed. The
time/date will not be stored between
power-ups.
0
00000447
Base Unit
minor
NTP Server Response Timeout
The unit could not contact the NTP
Server. The time/date will drift over
time.
0
00000448
Base Unit
warning
Internal Hardware Issue
An Internal Hardware Issue has
occured. The system may not
function properly.
0
00000449
Base Unit
minor
Host Build Version Mismatch
Host software is not at an officially
released version. Host function may
not be affected.
0
0000044A
Base Unit
minor
System Clock Not Locked
The system 27 MHz VCXO is not
locked. Check if the Mux SCR
Source is valid.
0
0000044B
Base Unit
minor
Chassis Identity Not
Programmed
The chassis identity of the host
could not be read correctly.
0
0000044C
Base Unit
minor
Selected Mux SCR Source is not
present
Selected Mux SCR Source could not
be detected. Check if the Sync Card
is plugged in.
0
0000044D
Base Unit
minor
Host Identity Not Programmed
The host identity could not be read
correctly.
0
0000044E
Base Unit
major
Uncontrolled release
This combination of host and option
card software is not officially
supported. This may lead to
unexpected behavior.
0
0000044F
Base Unit
minor
No identity license
This unit has not been licensed with
an identity.
0
00000450
Base Unit
critical
TS NIT is not valid
At one or more TS the Send
extended NIT (SIRG) parameter is
switched On, and one or more of the
parameters Operator, Longitude or
Latitude have invalid values.
0
00000680
Base Unit
major
Unsupported Option Card
The Option Card in Slot 1 is not
supported with this software release.
This may lead to unexpected
behaviour.
o
00000451
Base Unit
major
Summary of Contents for AVP 1000 1RU
Page 10: ...Preliminary Pages x EN LZT 790 0023 1 R16A BLANK...
Page 42: ...Installing the Equipment 2 18 EN LZT 790 0023 1 R16A BLANK...
Page 176: ...Front Panel Control 4 60 EN LZT 790 0023 1 R16A BLANK...
Page 319: ...Web GUI Control EN LZT 790 0023 1 R16A 5 143 Figure 5 43Support Page Device Management Tab...
Page 320: ...Web GUI Control 5 144 EN LZT 790 0023 1 R16A BLANK...
Page 324: ...Advanced Video Processing and Networking 6 4 EN LZT 790 0023 1 R16A BLANK...
Page 374: ...Options Licensing and Upgrades 7 28 EN LZT 790 0023 1 R16A BLANK...
Page 396: ...Preventive Maintenance and Fault finding 8 22 EN LZT 790 0023 1 R16A BLANK...
Page 444: ...Technical Specification B 28 EN LZT 790 0023 1 R16A BLANK...
Page 446: ...Audio Coding C 2 EN LZT 790 0023 1 R16A BLANK...
Page 452: ...Differences For Contribution Encoder and Voyager II D 2 EN LZT 790 0023 1 R16A BLANK...
Page 456: ...Differences For Contribution Encoder and Voyager II D 6 EN LZT 790 0023 1 R16A BLANK...
Page 458: ...Alarm Lists E 2 EN LZT 790 0023 1 R16A BLANK...
Page 500: ...Alarm Lists E 44 EN LZT 790 0023 1 R16A BLANK...
Page 502: ...Logo Creator F 2 EN LZT 790 0023 1 R16A BLANK...
Page 508: ...Logo Creator F 8 EN LZT 790 0023 1 R16A BLANK...