
Front Panel Control
EN/LZT 790 0023/1 R16A
4-23
unit with the same IP address within the network by sending out ARP
messages.
Control Interface Group
Network Mode
Same-Network, Different-Network. Read only parameter for the
control interface, and is set to Same-Network.
IP Redundancy Mode
Active-Active, Active-Standby. Describes how the spare interfaces will
behave. For the control port, it is set to Active-Standby and is read
only.
Index
Identifier of the interface group. Read only parameter.
Autorevert
Auto-revert to Primary, Auto-revert to Secondary. Shown only if the
IP
Redundancy mode
is set to Active-Standby. Determines what to do
when connection is lost.
Autorevert Delay
The delay in seconds before automatic redundancy switching takes
place. Shown only if the
IP Redundancy mode
is set to Active-
Standby.
Active Interface
Read only parameter. Displays which interface is active. In Active -
Active redundancy mode both interfaces are active.
Line Speed
Auto, 100 Mbps, 1 Gbps. The transmission speed of the link.
Duplex Mode
Auto, Full Duplex, Half Duplex. Determines whether data should be
transmitted and received in a time divided manner (Half Duplex) or
transmission and reception can happen at the same time over the
same link (Full Duplex). Auto is for automatic configuration.
Default MAC Address
Virtual MAC address assigned to the Control Interface Group.
IP Address
The IP address associated with the interface group.
Subnet Mask
The subnet mask associated with the interface group.
Gateway Address
The gateway address associated with the interface group.
Physical Control Interface <n>
The physical data interface labelled as Ge <n> of the current control
interface group.
Port Type
Ethernet. Read only parameter.
Direction
Output. Read only parameter.
Index
Identifier of the physical data interface. Read only parameter.
Default MAC Address
The hardware address of the Ge <n> interface.
Link Status
Link Down, Link Up. The status of the current physical data interface.
Link Up Time
The time in days, hours, minutes and seconds the link is established.
Read only parameter.
TX Packets
The packets transmitted since the link is up.
RX Packets
The packets received since the link is up.
IP Address
The IP address of the physical data interface.
Data Interface Group <n>
Network Mode
Same-Network, Different-Network. If set to Different-Network, the two
ports in the group can belong to different subnets. In Different-Network
mode only the Active-Active Redundancy mode is supported.
Summary of Contents for AVP 1000 1RU
Page 10: ...Preliminary Pages x EN LZT 790 0023 1 R16A BLANK...
Page 42: ...Installing the Equipment 2 18 EN LZT 790 0023 1 R16A BLANK...
Page 176: ...Front Panel Control 4 60 EN LZT 790 0023 1 R16A BLANK...
Page 319: ...Web GUI Control EN LZT 790 0023 1 R16A 5 143 Figure 5 43Support Page Device Management Tab...
Page 320: ...Web GUI Control 5 144 EN LZT 790 0023 1 R16A BLANK...
Page 324: ...Advanced Video Processing and Networking 6 4 EN LZT 790 0023 1 R16A BLANK...
Page 374: ...Options Licensing and Upgrades 7 28 EN LZT 790 0023 1 R16A BLANK...
Page 396: ...Preventive Maintenance and Fault finding 8 22 EN LZT 790 0023 1 R16A BLANK...
Page 444: ...Technical Specification B 28 EN LZT 790 0023 1 R16A BLANK...
Page 446: ...Audio Coding C 2 EN LZT 790 0023 1 R16A BLANK...
Page 452: ...Differences For Contribution Encoder and Voyager II D 2 EN LZT 790 0023 1 R16A BLANK...
Page 456: ...Differences For Contribution Encoder and Voyager II D 6 EN LZT 790 0023 1 R16A BLANK...
Page 458: ...Alarm Lists E 2 EN LZT 790 0023 1 R16A BLANK...
Page 500: ...Alarm Lists E 44 EN LZT 790 0023 1 R16A BLANK...
Page 502: ...Logo Creator F 2 EN LZT 790 0023 1 R16A BLANK...
Page 508: ...Logo Creator F 8 EN LZT 790 0023 1 R16A BLANK...