Alarm Lists
EN/LZT 790 0023/1 R16A
E-27
Alarm
Description
Port Number
Alarm ID
Source
Severity
OP-47 not detected on input
OP-47 data extraction is on but no
OP-47 data is present
1
010C4010
VBI
minor
Max ANC Data Rate Exceeded
The maximum bit-rate of the generic
ANC data output is exceeded. A
lower input ANC data rate is
required.
1
010C4011
VBI
warning
VPS not detected on input
Unable to find VPS data on any
of the configured lines. Please
check the video input. For more
details on the type of VBI, see
the VBI status page
1
010C4012
VBI
minor
Video 1 Encode Invalid
Configuration
An invalid configuration has been
applied to Main Channel. Check
Video Standard and Profile
selection.
0
010C4018
CE-x
Analogue
minor
Reflex PCR Exchange Timeout
PCR Exchange message not
received within timeout period
1
010C4020
CE-x
Analogue
Module
warning
Reflex SetRate Msg Timeout
Set Rate message not received
within timeout period
1
010C4021
CE-x
Analogue
Module
warning
Reflex Apply-Time out of range
Set Rate message received that is
too late to be applied, or is more
than 5 seconds early. The alarm is
cleared by the reception of a valid
Set Rate message, or Reflex being
disabled
1
010C4022
CE-x
Analogue
Module
warning
Reflex Source Identifier
Unstable
The online source identifier has
changed twice in the last three
messages received
1
010C4023
CE-x
Analogue
Module
warning
Reflex Source Identifier
Mismatch
The online source identifier in the set
rate messages does not match the
source identifier in the pcr exchange
messages. (The alarm is only raised
if this has occurred in two
consecutive PCR exchange
messages)
1
010C4024
CE-x
Analogue
Module
warning
Reflex Tracking PCR Exchange
Timeout
PCR Exchange message not
received from online encoder within
timeout period
1
010C4025
CE-x
Analogue
Module
warning
Audio Module Error
The audio module reported an
unexpected status value.
0
010C3FE0
Audio
Module 1
minor
Audio Module CPU loading
The audio module CPU load is too
high to support the current audio
configuration.
0
010C3FE1
Audio
Module 1
major
Audio DSP Failed to Boot
The audio DSP has failed to boot
0
010C3FE2
Audio
Module 1
major
Audio 1 Input lock
No valid audio detected on selected
input. Please check source
connection.
0
010C2000
Audio 1
major
Audio 1 TS input error
Incoming transport stream error.
Please check source TS.
0
010C2001
Audio 1
major
Summary of Contents for AVP 1000 1RU
Page 10: ...Preliminary Pages x EN LZT 790 0023 1 R16A BLANK...
Page 42: ...Installing the Equipment 2 18 EN LZT 790 0023 1 R16A BLANK...
Page 176: ...Front Panel Control 4 60 EN LZT 790 0023 1 R16A BLANK...
Page 319: ...Web GUI Control EN LZT 790 0023 1 R16A 5 143 Figure 5 43Support Page Device Management Tab...
Page 320: ...Web GUI Control 5 144 EN LZT 790 0023 1 R16A BLANK...
Page 324: ...Advanced Video Processing and Networking 6 4 EN LZT 790 0023 1 R16A BLANK...
Page 374: ...Options Licensing and Upgrades 7 28 EN LZT 790 0023 1 R16A BLANK...
Page 396: ...Preventive Maintenance and Fault finding 8 22 EN LZT 790 0023 1 R16A BLANK...
Page 444: ...Technical Specification B 28 EN LZT 790 0023 1 R16A BLANK...
Page 446: ...Audio Coding C 2 EN LZT 790 0023 1 R16A BLANK...
Page 452: ...Differences For Contribution Encoder and Voyager II D 2 EN LZT 790 0023 1 R16A BLANK...
Page 456: ...Differences For Contribution Encoder and Voyager II D 6 EN LZT 790 0023 1 R16A BLANK...
Page 458: ...Alarm Lists E 2 EN LZT 790 0023 1 R16A BLANK...
Page 500: ...Alarm Lists E 44 EN LZT 790 0023 1 R16A BLANK...
Page 502: ...Logo Creator F 2 EN LZT 790 0023 1 R16A BLANK...
Page 508: ...Logo Creator F 8 EN LZT 790 0023 1 R16A BLANK...