Alarm Lists
EN/LZT 790 0023/1 R16A
E-11
Alarm
Description
Port Number
Alarm ID
Source
Severity
Reflex Source Identifier
Unstable
The online source identifier has
changed twice in the last three
messages received
1
010C4023
VCM
Module
warning
Reflex Source Identifier
Mismatch
The online source identifier in the set
rate messages does not match the
source identifier in the pcr exchange
messages. (The alarm is only raised
if this has occurred in two
consecutive PCR exchange
messages)
1
010C4024
VCM
Module
warning
Reflex Tracking PCR Exchange
Timeout
PCR Exchange message not
received from online encoder within
timeout period
1
010C4025
VCM
Module
warning
Audio Module Error
The audio module reported an
unexpected status value.
0
010C3FE0
Audio
Module 1
minor
Audio Module CPU loading
The audio module CPU load is too
high to support the current audio
configuration.
0
010C3FE1
Audio
Module 1
major
Audio DSP Failed to Boot
The audio DSP has failed to boot
0
010C3FE2
Audio
Module 1
major
Audio 1 Input lock
No valid audio detected on selected
input. Please check source
connection.
0
010C2000
Audio 1
major
Audio 1 TS input error
Incoming transport stream error.
Please check source TS.
0
010C2001
Audio 1
major
Audio 1 Compressed audio not
detected
Compressed audio not detected on
input. Please check source
connection and source format.
0
010C2002
Audio 1
minor
Audio 1 Input frame CRC failure
CRC error in compressed input
frame. Output is muted.
0
010C2003
Audio 1
minor
Audio 1 Unsupported sample
rate
Unsupported sample rate at decoder
output.
0
010C2004
Audio 1
minor
Audio 1 Dolby E program not
present
Program not present in Dolby E
stream.
0
010C2005
Audio 1
minor
Audio 1 Dolby E alignment
Dolby E frames not properly aligned
to video frames. May glitch on frame
drop/repeat and video may not be
aligned to audio.
0
010C2006
Audio 1
minor
Audio 1 Dolby E metadata frame
rate mismatch
Frame rate indicated in Dolby E
metadata does not match current
video frame rate.
0
010C2007
Audio 1
minor
Audio 1 ADS control track
Control track for audio description
not present.
0
010C2008
Audio 1
minor
Audio 1 ADS silence
Silent period detected. Valid only for
Audio Description Service encoding.
0
010C2009
Audio 1
minor
Summary of Contents for AVP 1000 1RU
Page 10: ...Preliminary Pages x EN LZT 790 0023 1 R16A BLANK...
Page 42: ...Installing the Equipment 2 18 EN LZT 790 0023 1 R16A BLANK...
Page 176: ...Front Panel Control 4 60 EN LZT 790 0023 1 R16A BLANK...
Page 319: ...Web GUI Control EN LZT 790 0023 1 R16A 5 143 Figure 5 43Support Page Device Management Tab...
Page 320: ...Web GUI Control 5 144 EN LZT 790 0023 1 R16A BLANK...
Page 324: ...Advanced Video Processing and Networking 6 4 EN LZT 790 0023 1 R16A BLANK...
Page 374: ...Options Licensing and Upgrades 7 28 EN LZT 790 0023 1 R16A BLANK...
Page 396: ...Preventive Maintenance and Fault finding 8 22 EN LZT 790 0023 1 R16A BLANK...
Page 444: ...Technical Specification B 28 EN LZT 790 0023 1 R16A BLANK...
Page 446: ...Audio Coding C 2 EN LZT 790 0023 1 R16A BLANK...
Page 452: ...Differences For Contribution Encoder and Voyager II D 2 EN LZT 790 0023 1 R16A BLANK...
Page 456: ...Differences For Contribution Encoder and Voyager II D 6 EN LZT 790 0023 1 R16A BLANK...
Page 458: ...Alarm Lists E 2 EN LZT 790 0023 1 R16A BLANK...
Page 500: ...Alarm Lists E 44 EN LZT 790 0023 1 R16A BLANK...
Page 502: ...Logo Creator F 2 EN LZT 790 0023 1 R16A BLANK...
Page 508: ...Logo Creator F 8 EN LZT 790 0023 1 R16A BLANK...