Preventive Maintenance and Fault-finding
EN/LZT 790 0023/1 R16A
8-11
8.5.5
Cannot Access Web GUI
In the event that you cannot access the web GUI, refer to
Table 8.5 Cannot Access Web GUI
Step
Action
If Result of Action is Yes…
If Result of Action is No…
1
Check whether the unit can be
pinged.
Proceed to next step.
Follow the instructions given in
Unit Cannot Be Pinged
.
2
If the loading of the unit control
interface is stuck with a warning
message "Use of this browser
configuration is not officially
supported by Ericsson TV",
check whether the Internet
Explorer 8 is used in
compatibility mode. Is it?
Turn off the compatibility mode
in Internet Explorer 8 by
following the steps below:
1. Press the
Alt
key, then
select the
Tools
menu.
2. Select
Compatibility View
Settings
.
3. Make sure that all the three
checkboxes at the bottom are
unchecked.
4. Click
Close
.
5. Re-open the browser.
Proceed to next step.
3
Does a dialogue appear after
accessing the interface
requesting the user name and
password?
Give the credentials set
before. (The default user
name is "engineer", the default
password is "password".) Not
remembering the user name
or the password, contact the
customer services.
If the procedures given here
cannot solve the problem,
contact the customer services.
8.5.6
Unit Cannot Be Pinged
Pinging a computer is a method of checking if a computer is on the network. Pings
send a network request to a computer asking it to respond (ICMP
ECHO_REQUEST).
To ping a computer from a Windows/PC machine, use the MSDOS prompt and type
the command:
ping <IP address>
A successful ‘ping’ consists of receiving back a copy of a short transmitted test
message. The reply will display ‘ping statistics’ (number of packets sent and
received and the time taken, in ms, to receive back those packets.
In the event that you cannot ping your unit, refer to
Summary of Contents for AVP 1000 1RU
Page 10: ...Preliminary Pages x EN LZT 790 0023 1 R16A BLANK...
Page 42: ...Installing the Equipment 2 18 EN LZT 790 0023 1 R16A BLANK...
Page 176: ...Front Panel Control 4 60 EN LZT 790 0023 1 R16A BLANK...
Page 319: ...Web GUI Control EN LZT 790 0023 1 R16A 5 143 Figure 5 43Support Page Device Management Tab...
Page 320: ...Web GUI Control 5 144 EN LZT 790 0023 1 R16A BLANK...
Page 324: ...Advanced Video Processing and Networking 6 4 EN LZT 790 0023 1 R16A BLANK...
Page 374: ...Options Licensing and Upgrades 7 28 EN LZT 790 0023 1 R16A BLANK...
Page 396: ...Preventive Maintenance and Fault finding 8 22 EN LZT 790 0023 1 R16A BLANK...
Page 444: ...Technical Specification B 28 EN LZT 790 0023 1 R16A BLANK...
Page 446: ...Audio Coding C 2 EN LZT 790 0023 1 R16A BLANK...
Page 452: ...Differences For Contribution Encoder and Voyager II D 2 EN LZT 790 0023 1 R16A BLANK...
Page 456: ...Differences For Contribution Encoder and Voyager II D 6 EN LZT 790 0023 1 R16A BLANK...
Page 458: ...Alarm Lists E 2 EN LZT 790 0023 1 R16A BLANK...
Page 500: ...Alarm Lists E 44 EN LZT 790 0023 1 R16A BLANK...
Page 502: ...Logo Creator F 2 EN LZT 790 0023 1 R16A BLANK...
Page 508: ...Logo Creator F 8 EN LZT 790 0023 1 R16A BLANK...