Preventive Maintenance and Fault-finding
8-10
EN/LZT 790 0023/1 R16A
Step
Action
If Result of Action is Yes…
If Result of Action is No…
3
Check Power Cable and Fuse
.
Unplug the power connector
from the unit and try it in another
piece of equipment. Does it
work?
The problem lies within the
unit. Proceed to next step.
The problem lies with either the
cable itself, or with the fuse in
the plug. Replace the fuse or try
to substitute another cable.
4
Check PSU Module(s) and
Fuse(s)
. Ensure the power
connector is unplugged.
Remove the fuse from the rear
panel connector and inspect it.
Has the fuse blown?
Replace the fuse with one of
the correct type and rating
(see
Annex B Technical
Specification)
. If the PSU still
does not work, unplug the
power cable and call a Service
Engineer.
Possible problem with the PSU
module. Call a Service Engineer.
8.5.3.1
Fuse Replacement
Please refer to the
Installation, Safety and Compliance Information for Ericsson
Compression Products Reference Guide
supplied with your product for full details of
how to replace the fuse in your product.
8.5.3.2
Lithium Battery
The lithium battery fitted within this product is not user replaceable and as such
should only be replaced by qualified service personnel.
8.5.4
Fan(s) Not Working/Overheating
The fan speed can be reduced (set to lowest noise) at low temperatures to allow the
unit to quickly attain operational temperature. In the event of overheating problems,
refer to
Note:
Failure to ensure a free air-flow around the unit may cause overheating.
This condition is detected by a temperature sensor; it may be used to trigger
an automatic alarm.
Table 8.4 Fans Not Working/Overheating
Step
Action
If Result of Action is Yes…
If Result of Action is No…
1
Check Fan Rotation
. Inspect
the fans located at the sides of
the enclosure. Are the fans
rotating? Check Base Board
temperature and fan (see
nCompass information).
Check that the unit has been
installed with sufficient space
allowed for air-flow (see
Chapter 2, Installing the
Equipment
). If the ambient air
is too hot, additional cooling
may be required.
Possible break in the DC supply
from the PSU module to the
suspect fan(s). Call a Service
Engineer.
Summary of Contents for AVP 1000 1RU
Page 10: ...Preliminary Pages x EN LZT 790 0023 1 R16A BLANK...
Page 42: ...Installing the Equipment 2 18 EN LZT 790 0023 1 R16A BLANK...
Page 176: ...Front Panel Control 4 60 EN LZT 790 0023 1 R16A BLANK...
Page 319: ...Web GUI Control EN LZT 790 0023 1 R16A 5 143 Figure 5 43Support Page Device Management Tab...
Page 320: ...Web GUI Control 5 144 EN LZT 790 0023 1 R16A BLANK...
Page 324: ...Advanced Video Processing and Networking 6 4 EN LZT 790 0023 1 R16A BLANK...
Page 374: ...Options Licensing and Upgrades 7 28 EN LZT 790 0023 1 R16A BLANK...
Page 396: ...Preventive Maintenance and Fault finding 8 22 EN LZT 790 0023 1 R16A BLANK...
Page 444: ...Technical Specification B 28 EN LZT 790 0023 1 R16A BLANK...
Page 446: ...Audio Coding C 2 EN LZT 790 0023 1 R16A BLANK...
Page 452: ...Differences For Contribution Encoder and Voyager II D 2 EN LZT 790 0023 1 R16A BLANK...
Page 456: ...Differences For Contribution Encoder and Voyager II D 6 EN LZT 790 0023 1 R16A BLANK...
Page 458: ...Alarm Lists E 2 EN LZT 790 0023 1 R16A BLANK...
Page 500: ...Alarm Lists E 44 EN LZT 790 0023 1 R16A BLANK...
Page 502: ...Logo Creator F 2 EN LZT 790 0023 1 R16A BLANK...
Page 508: ...Logo Creator F 8 EN LZT 790 0023 1 R16A BLANK...