b. While holding the center of the media on the
platen, pull it out by moving it toward yourself,
and slacken the media at the front side.
c. Hold down the Manual switch on the
side to take-up the slack media around the core.
c
Important:
When taking-up the media around the core,
do take-up of only the slackened part. If you do
take-up without slackening, it will cause
problems, such as wrinkles.
E
Flip the Auto switch to
.
F
Lower the media loading lever.
G
Confirm that the media is attached without
looseness on the front and back sides.
If the tension on the left and right of the media is
different in the areas shown in the illustration
below, the media will not be taken up correctly.
When one side is loose, restart the procedure
from Step 2.
Note:
You can confirm differences in tension by lightly
tapping both edges of the media as shown in the
illustration below.
SC-F10000H Series/SC-F10000 Series User's Guide
Basic Operations
86