121
Automatic
CasaConnect KNX Control Center
• Version: 13.09.2021 • Technical changes and errors excepted.
Night back cooling:
Touch the field to set the times for night back cooling. The setting is only active if the
general settings for night back cooling have already been applied.
System > Set automatic > General settings > Night back cooling
6.3.5. Set night back cooling (ventilation), Page 107
Enable one or more periods in the list. If you want to change the periods, touch the tool
icon.
6.3.3. Set time switch period, Page 106
Be careful that your timer settings do not prevent night back cooling operations!
NBC: Indoor temperature (night back cooling):
Shows the indoor temperature, to which room is cooled. Touch the field to set the in-
door temperature, until which the window remains open during the night back cooling.
The setting will only be activated once a night back cooling temperature has been set.
Default setting: 20.0°C.
NBC: Actuation (night back cooling):
Shows the actuation position in percent during night back cooling. Touch the field to
set the position using a slider (0% = closed, 100% = fully open). The setting will only be
activated once a night back cooling temperature has been set.
Default setting: 30%.
Timed ventilation:
Touch the field to set the ventilation period. Enable one or more periods in the list. If
you want to change the periods, touch the tool icon.
6.3.3. Set time switch period, Page 106
The window is only opened if the set outdoor temperature is reached. At the end of the
ventilation time, normal automatic ventilation takes place according to temperature
and humidity.
Timed ventilation: Actuation position:
Shows the position to which the window opens if timed ventilation is active. The set-
ting is only active if timed ventilation has been switched on. Touch the field and set the
maximum open position (0% = closed, 100% = fully open).
Default setting: 100%.
The window can still be fully opened manually.
Colour restriction:
Shows whether the movement limit is switched on for lower outside temperatures for
this window. Touch the field to change the setting.