Basic settings in the ETS
CasaConnect KNX Control Center
• Version: 13.09.2021 • Technical changes and errors excepted.
Type of output: Input 32bit counter without mathematical sign
Type of output: Input 32bit counter with mathematical sign
Type of output: Input 32bit floating point
Display value = Value of bus * a * b
Bus value = Input value / a / b
Conversion factor a
-0.0001 • 0.0001 ... -10000 • 10000; 1
Conversion factor b
1 ... 65535
Unit
[Free text]
Value can be adjusted via display
No • Yes
Start value (in 0.1)
-2147483648 ... 2147483647; 0
Minimum value (in 0.1)
(
only if value can be set via display)
-2147483648 ... 2147483647
Maximum value (in 0.1)
(
only if value can be set via display)
-2147483648 ... 2147483647
Unit
[Free text]
Value can be adjusted via display
No • Yes
Start value
0 ... 4294967295
Minimum value
(
only if value can be set via display)
0 ... 4294967295
Maximum value
(
only if value can be set via display)
0 ... 4294967295
Unit
[Free text]
Value can be adjusted via display
No • Yes
Start value
-2147483648 ... 2147483647; 0
Minimum value
(
only if value can be set via display)
-2147483648 ... 2147483647
Maximum value
(
only if value can be set via display)
-2147483648 ... 2147483647
Conversion factor a
-0.0001 • 0.0001 ... -10000 • 10000; 1
Conversion factor b
1 ... 65535
Unit
[Free text]
Value can be adjusted via display
No • Yes
Start value (in 0.1)
-2147483648 ... 2147483647; 0
Minimum value (in 0.1)
(
only if value can be set via display)
-2147483648 ... 2147483647
Maximum value (in 0.1)
(
only if value can be set via display)
-2147483648 ... 2147483647