MP500/4N-8-16 Programming
17
1.3
DK500M-E ELECTRONIC KEY READERS
Figure 5 - DK500M-E electronic key readers
Ref.
Description
Use or indications provided
Operating mode = Mode 3
Operating mode = Mode 2
A B
C D
LED (green)
associated
partition status
Off
* = all partitions associated to the LED are
disarmed
On
*
= all partitions associated to the LED are
armed
Blinking
* = at least one partition associated
to the LED is armed
Off
= all partitions associated to the LED are
disarmed
On
= all partitions associated to the LED are
armed
Blinking
= at least one partition associated to
the LED is armed
E
LED (red)
alarms and indications
Off
= no indications for the partitions
associated to the reader
On
= alarm indication stored for the partitions
associated to the reader or tamper or system
failure (the indication only appears when the
system is disarmed)
Blinking
= presence of at least one open
input in the partitions associated to the reader.
The indication only appears when the system is
disarmed.
The LED will light up fixed if there are alarms, or
failures and open inputs at the same time.
This LED lights up to indicate the need to check
indication details on the keypad.
Off
= no indications for the partitions
associated to the reader
On
= alarm indication stored for the partitions
associated to the reader or tamper or system
failure (the indication only appears when the
system is disarmed)
Blinking
= presence of at least one open
input in the partitions associated to the reader.
The LED will light up fixed if there are alarms, or
failures and open inputs at the same time.
This LED lights up to indicate the need to check
indication details on the keypad.
F
Electronic keyhole
Shaped hole for inserting the DK50 electronic key
Mode 3 is EN50131 grade 3 compliant.
IMPORTANT!
Mode 3 is not available for the MP500/4N control panel because this device is EN50131 grade 2, and not
grade 3, compliant.
Mode 2 is EN50131 grade 2 compliant.
*
) The LED will remain off in a EN50131 grade 3 compliant system even if an indication is present. Insert the key and remove i t to
check system status: the LEDs associated to active partitions will light up for a few seconds (fixed or blinking).
Summary of Contents for MP500/16