MP500/4N-8-16 Programming
41
O OR TC
The OR TC output is activated when at least one of the partition associated to it is armed.
O ARM WARNING
The arm warning output is activated when the programmed warning time for executing a partition arming command by the timed
programmer starts.
O FAILURE
The failure output is activated if a input failure event is generated.
O BURGL/TAMPER
The burglar/tamper output is activated when a burglar or tamper or wrong code event is generated.
O DETECT.FAILURE
The detector failure output is activated if an event is generated by a detector failure input or a jamming failure input.
The following customisations are not EN50131 compliant because they are not described in this standard.
O SILENT PANIC
The silent panic output is activated if a silent panic fault event is generated.
O AUDIBLE PANIC
The audible panic output is activated if a panic event is generated.
O HOLD-UP
The hold-up output is activated if a hold-up event is generated.
O EMERGENCY
The emergency output is activated if an emergency event is generated.
O TECHNOL.TYPE 1
The technological type 1 output is activated if a technological type 1 event is generated.
O TECHNOL.TYPE 2
The technological type 2 output is activated if a technological type 2 event is generated.
O TECHNOL.TYPE 3
The technological type 3 output is activated if a technological type 3 event is generated.
O FIRE ALARM
The fire alarm output is activated if a fire event is generated.
O RESET FIRE AL
The reset fire alarm output is activated if a reset fire alarm is opened.
O GONG
The gong output is activated if an input to which the ancillary gong function is assigned is opened.
O OPEN INPUT
The open input output is activated when at least one of the inputs which belong to the partitions assigned to it or a test input is
activated.
IMPORTANT!
The open input output is used to notify the state of the input and cancels EN50131 grade 3 compliance.
O INPUT ISOLATED
The input isolated output is activated when at least one of the inputs belonging to the partitions associated to it is isolated in any
manner or for any reason.
IMPORTANT!
The input isolated output is used to notify the state of the input and cancels EN50131 grade 3 compliance.