![Elkron MP500/16 Programming Manual Download Page 30](http://html.mh-extra.com/html/elkron/mp500-16/mp500-16_programming-manual_2393492030.webp)
30
MP500/4N-8-16 Programming
4.7
LCD INFO
The keypad can display the following information when the system is in stand-by:
date and time
system partition status
system area status
The viewing mode may be independently elected for each keypad in the system.
IMPORTANT!
The entire system will lose EN50131 grade 3 compliance if only one keypad in the system permanently displays
information other than date and time.
To change the display view in stand-by:
1) Press
.
2) Press
.
3) Press
.
4) Enter
<User code>
and then
.
5) Use
and
to select the information to be displayed: date and time, areas synoptic, synoptic
(partitions). Press
to confirm.
6) Press
repeatedly to exit from the menu.
4.8
HOW TO SET DATE AND TIME
In addition to being shown on the keypad in stand-by viewing mode (see
), date and time information is used to record
events on the Event Log and on the Diagnose Log and for the timed programmer functions. So, the timed programmer will not work
properly if the date and time are not correct and the Event and Diagnose Log time references will not be correct.
Proceed as follows to modify the date and time shown on the display:
1) Enter
<Master / Installer code>
, press
, then
and finally press
repeatedly until
SETTINGS appears.
2) Press
.
3) Press
.
4) Press
.
5) Enter the time in hh:mm (24 hour) format directly using the number keys using an initial 0 if
needed. If you make a mistake press
and access the SET HOUR menu.
6) Press
to confirm the entered time then
.
MP500/16
22/01/2014 15:20
SYSTEM STATUS
□□■■□•••••••••••
AREAS STATUS
□□••
SYSTEM STATUS
SERVICE MESSAGE
SYSTEM STATUS
LCD INFO
ENTER CODE
LCD INFO
DATE/TIME
UT01:MASTER
SETTINGS
SETTINGS
HOUR - DATE
HOUR - DATE
SET HOUR
SET HOUR
HOUR 10:05
HOUR - DATE
SET DATE
Summary of Contents for MP500/16
Page 139: ...MP500 4N 8 16 Programming 139 ...