MP500/4N-8-16 Programming
5.5.2
Partial arming
The partial arming of only some partitions in the system is possible only if the remote control is duly programmed to do so.
Press
on the remote control to arm the partitions to which the remote control is assigned. The remote control buzzer will beep if the
control panel acknowledges the command.
Note:
The some partitions assigned to the remote control can be armed/disarmed also by using the
(toggle) key. Importantly,
this key works as follows:
1. Pressing the key will cause the partition status to switch from disarmed to armed and vice versa (toggle).
2. If the partitions assigned to the remote control are partially armed (partial arming), pressing the key will arm all partitions: any
partitions which are disarmed will be armed.
3. Pressing the key again will cause the partitions to be totally disarmed (not only the previously armed partitions).
5.6
DISARMING PROCEDURE
The arm system may be disarmed in various manners, some of which are not EN50131 compliant.
EN50131 compliant modes are: disarming from keypad, disarming with electronic or proximity key, disarming by timed programmer or
disarming from a specialised input using a mechanical key.
Remote disarming, disarming by GSM and DTMF commands and disarming by remote control are not EN50131 compliant.
The authorisation codes which must be used with keypads are described in paragraph
It is possible to disarm the entire system, only some partitions or one or more areas, if these are programmed. Areas allow operating
on a subset of partitions at the same time without needing to select them each time.
The user or key must have been assigned to the partition or area during programming in order to operate it.
5.7
DISARMING FROM KP500D/N AND KP500DV/N KEYPADS
5.7.1
Total disarming (system with partitions only)
Proceed as follows to disarm the entire alarm system if no areas are defined:
1) Enter
<Master / User / Installer / Technical Manager code>
.
2) The keypad will beep. Press
to exit without disarming. The status LED will switch off after 5
seconds and the following will appear on the display
3) Press
again if you do not want to wait for 5 seconds.
4) The display will go back to standard view automatically after one minute. Press
to go to
standard view immediately.
IMPORTANT!
The user will disarm only the assigned partitions and not necessarily all the
partitions even with this procedure.