MP500/4N-8-16 Programming
99
Cause
LED
Log
M
e
m
ory
Description of the event
(Event Log and Diagnose Log)
Auxiliary
indication
(controlled
output)
Telephone
message
Keypad
Reader
Detector fault input alarm
■
Inxxx:name
DETECTOR FAILURE
Detector fault
Anomaly
Siren failure input alarm
■
■
Inxxx:name
SIREN FAILURE
System failure
Anomaly
Fault input alarm
■
■
Inxxx:name
FAILURE
Failure
Anomaly
Jamming fault input alarm
■
■
Inxxx:name
JAMMING
Detector fault
Anomaly
External communicator fault
input alarm
■
■
Inxxx:name
COM. FAULT
Telephone fault
Anomaly
Other faults
■
System failure
Failure
No communication with device
on bus
■
■
BUS COMM.FAILURE BUS
device (DDxx:name)
Sys fault
System tamper
Isolated inputs
■
Inxxx:name
Isolated inputs
Excluded input
Inhibited inputs (temporarily
during arming)
■
INHIBIT
Isolated inputs
Excluded input
After having entered 21 wrong
codes
■
■
WRONG CODE
device (DDxx:name)
Tamper
Tamper or SAB input indicating
tampering
■
■
device (DDxx:name)
Tamper
System tamper
Balanced input imbalance
■
■
Inxxx:name
IN customisation
Tamper
System tamper
Radio jamming
■
■
JAMMING
device (DDxx:name)
Tamper
Radio tamper
No wireless device supervision
■
■
SUPERVISION
device (DDxx:name)
Tamper
Radio tamper
Enter menu with installer code
■
Open input
■
Inxxx:name
IN customisation
Open input
Test input opening
■
■
Inxxx:name
INPUT OF TEST
Open input
PO warning / arm partitions /
enable-disable user or key /
enable-disable output
■
PO warning
Instantaneous lack of power
*
POWER INSTANT. (START/END)
"Lack of power" after
programmed timeout
*
■
POWER (START/END)
Lack of power
Power mains
fault/restored
Arm/disarm partitions
■
EXECUTED or PARTIALLY
DONE
Partition status
Armed Partition xx
Disarmed partition xx
Override partition arming
■
SETT. OVERRIDDEN
Partition status
System block, no mains power,
battery not OK
ARREST SYSTEM
Enter valid code on KPxx keypad
■
VALID CODE
Edit date-time on KPxx keypad
■
Date Time + KPxx: name
Enable/disable code
■
Start user en KPxx: name
Arm partition command not
executed
■
NOT EXECUTED
Arming not
executed
Hold-up alarm
■
ALARM HOLD-UP
Hold-up
Attack in progress
Inhibit tamper input
INHIB. TAMPER IN TAMPER IN
IDP call from PSTN module
(with positive result)
IDP-OK
IDP call from PSTN module
(with negative result)
IDP-KO
* The LED will go from fixed to blinking in case of “Instantaneous lack of power” and will continue to blink until the power is restored in
case of “Lack of power after programmed timeout”.
Table 13 - Indication overview
Summary of Contents for MP500/16
Page 139: ...MP500 4N 8 16 Programming 139 ...