46
MP500/4N-8-16 Programming
4.14 READER PROGRAMMING
4.14.1
LED management
The reader LEDs may be freely assigned to one or more system partitions.
Different associations may be implemented for each reader but it is not possible to associate a same partition to several LEDs of the
same reader.
The green LEDs display the associated partition status.
The red LED shows anomalies (open inputs, alarms).
The masking function hides system status (armed or disarmed) when it is enabled. The reader LEDs will be off.
System status may be checked when the masking function is enabled by inserting a valid key.
IMPORTANT!
Do not enable masking to maintain EN50131 compliance. The LEDs are managed directly by the control panel.
4.14.2
Programming procedure
Proceed as follows to program the readers:
1) Enter
<Installer code>
, press
, then
and finally
repeatedly until PROGRAMMING
appears.
2) Press
and then
.
3) Press
.
4) Press
and
to select the required reader. Press
to confirm the selection.
5) Press
. Press
and
to select the concerned LED. Press
to confirm.
6) The screen page shown here by the side will appear. The empty boxes represent partitions which
are not assigned to the LED and the black boxes the partitions which have already been assigned.
The partitions already assigned to another LED of the reader will not be displayed. Press
and
to select the partition to be associated. Press
and
to assign the partition (the square
will turn black) or to disassociate it (the square will appear empty). Repeat the procedure for all
partitions to be assigned to the output. Press
at the end.
7) Repeat the procedure from step 5 for the other LEDs, if necessary (it is not necessary to assign all
LEDs to partitions).
8) Press
and then
.
9) Press
. Press
and
to enable or disable masking. Press
to confirm.
IMPORTANT!
Do not enable masking to maintain EN50131 compliance. The LEDs are
managed directly by the control panel.
10) Press
.
11) Press
. Enter a descriptive name for the reader using the keypad (see paragraph
). The name can be up to 24 characters long. Press
to confirm.
12) Press
to program the other readers repeating the procedure from step 3.
13) Press
repeatedly to exit from the menu.
IMPORTANT!
Program all readers used in the system.
UT00:INSTALLER
PROGRAMMING
PROGRAMMING
READERS
READERS
DK01:DK 01
DK01:DK 01
ASSIGN
ASSIGN
LED 1 |
|
SE01:
□□□□□■□
ASSIGN
LED 1 |
|
DK01:DK 01
MASKING
DK01:DK 01
NAME
NAME
DK01:DK 01
Summary of Contents for MP500/16