9.10 EN50131 DEGREE COMPLIANCE
By factory setting, the behaviour of MP500/8 and MP500/16 systems is EN50131 grade 3 compliant, and that of MP500/4N system is
EN50131 grade 2 compliant.
Some settings may be changed individually during programming. Others, such as system status visibility, indications and methods of
use of readers, may be varied as a whole by selecting th
e relevant “Use mode”.
Mode 3 is the only one to be EN50131 grade 3 compliant. Mode 2 is EN50131 grade 2 compliant.
Mode 0 is not compliant to any standard. Mode 3 is not available for MP500/4N control panel.
Some differences of behaviour in Mode 3 and in Mode 2 are described in paragraphs
Use of LEDs and icons with EN50131
System in use mode = Mode 3 (EN50131 grade 3 compliant)
5.4.4.1 System in use mode = Mode 3
IMPORTANT!
The settings of the alarm system are not changed if the mode is changed.
For example, if the mode of a fully EN50131 grade 3 compliant systems is changed from Mode 3 to Mode 2, compliance will
be lost. Simply set Mode 3 again to regain compliance.
On the other hand, if the alarm system settings and its hardware configuration are not EN50131 grade 3 compliant it will not be
enough to set Mode 3 to make the alarm system EN50131 grade 3 compliant.
To change the use mode of the system:
1) Enter
<Installer code>
, press
, then
and finally
repeatedly until MAINTENANCE
appears.
2) Press
and then
several times until USE MODE appears.
3) Press
. Press
and
to select the mode. Press
to confirm.
IMPORTANT!
By setting Mode 2 or Mode 0 the system will lose EN50131 grade 3
compliance.
IMPORTANT!
The Operation Mode 0 is only available starting from control panels with SW
version 1.01 and starting from keypad SW version 1.03.
4) Press
repeatedly to exit from the menu.
9.11 HOW TO ACQUIRE BUS DEVICES
The procedure for acquiring a bus device (expansion module, keypad, reader) is contained in the
Installation Manua
l.
9.12 HOW TO DELETE BUS DEVICES
The procedure for deleting a bus device (expansion module, keypad, reader) is contained in the
Installation Manual
.