MP500/4N-8-16 Programming
75
5.2.3
Partial arming (system with partitions only)
Proceed as follows to arm the alarm system partially if no areas are defined:
1) Enter
<Master / User / Installer / Technical Manager code >
and press
.
2) The keypad will beep. Press
to exit without arming.
3) Enter the number of the partitions to be armed on the keypad: the respective squares will turn black.
IMPORTANT!
Simply enter the number directly if nine or fewer partitions have been
programmed. If more than nine partitions have been programmed, always enter two digits to
select the partitions, including for numbers from 1 to 9 (1 = 01, 2 = 02 etc.).
4) The status LED will light up after 5 seconds (fixed if all partitions are armed, blinking if some
partitions are not armed). Press
again if you do not want to wait for 5 seconds.
5) If programmed or if the system is EN50131 compliant, the keypad will sound long beeps initially
followed by short beeps for the last 10 seconds.
6) The display will go back to standard view automatically after one minute. Press
to go to
standard display immediately.
IMPORTANT!
The user will arm only the assigned partitions and not necessarily all the partitions even with this procedure.
5.2.4
Partial arming (system with areas and partitions)
Proceed as follows to arm the entire alarm system if areas are defined:
1) Enter
<Master / User / Installer / Technical Manager code >
and press
.
2) Enter
or
on the keypad. The procedure will continue as for partitions only if you press
.
If you press
:
3) The keypad will beep. Press
to exit without arming.
4) Enter the number of the partitions to be armed on the keypad: the respective squares will turn black.
5) The status LED will light up after 5 seconds (fixed if all areas are armed, blinking if some areas are
not armed) and all the areas will appear on the display. Press
again if you do not want to wait for
5 seconds.
6) If programmed or if the system is EN50131 compliant, the keypad will sound long beeps initially
followed by short beeps for the last 10 seconds.
7) The display will go back to standard view automatically after one minute. Press
to go to
standard display immediately.
IMPORTANT!
The user will arm only the assigned areas and not necessarily all the areas even with this procedure.
ARM
□□□□••••••••••••
EXECUTED
■□□■••••••••••••
1)AREAS
2)PARTITIONS
ARM
□□••
EXECUTED
■□••
Summary of Contents for MP500/16