MP500/4N-8-16 Programming
111
7.4.2
Arming warning
This is generated
when...
The programmed warning time for executing a partition arming command by the timed programmer is
elapsing.
It lasts...
For until the partitions are armed or a postpone command is imparted.
It is activated on...
Enabled and associated keypads with one beep per minute.
The programmed arming warning outputs which have at least one partition in common with the arming
input.
7.4.3
Gong
This is generated
when...
An input on which the ancillary gong function was enabled is opened and all the partitions to which it is
associated are disarmed.
It is activated on...
Enabled and associated keypads with two consecutive beeps.
On programmed gong outputs which have at least one partition in common for one second.
7.4.4
System status by means of wireless sirens
Some sirens can indicate the system status, i.e. arming and disarming by means of the remote control or other means, either local or
remote. The behaviour is comparable to that of car anti-theft systems which indicate arming and disarming by beeping and flashing the
indicators.
This is generated
when...
One or more partitions or the entire system is armed/disarmed (if appropriately programmed).
It is activated on...
Sirens inside and outside the system.
It is indicated on...
Sirens by means of auditory only or auditory-visual indication:
HP500 arming = 1 beep + 1 blink; disarming = 2 beeps + 1 sequential blink
IS500 arming = 1 beep; disarming = 2 beeps
7.5
DESCRIPTION OF VOCAL INDICATIONS
The vocal indications are available only on KP500DV/N keypads. The control panel must be equipped with a vocal module.
7.5.1
Arming/disarming message
This is generated
when...
One or more partitions are armed or disarmed by means of a vocal keypad.
One or more areas are armed or disarmed by means of a vocal keypad.
It is activated on...
Keypads enabled for this service.
The following
sentence is listened...
For arming:
“Arming executed”
followed by the vocal names recorded for the single armed partitions.
For disarming:
“Disarmed”
followed by the vocal names recorded for the single disarmed partitions.
If arming fails in one or more partitions:
“Activation not done”,
followed by the vocal names recorded for the single partitions which were not armed
because one or more inputs are open.
“Warning: open input”.
In case of arming with automatic inhibition of the open inputs:
“Arming executed”
followed by the vocal names recorded for the single armed partitions.
“Warning: open excluded”.
It is stopped by...
Pressing
IMPORTANT!
The automatic inhibition function is not EN50131 compliant. The function cancels EN50131 compliance of the
entire system.
Summary of Contents for MP500/16
Page 139: ...MP500 4N 8 16 Programming 139 ...