HOW TO ACTIVATE COMMANDABLE OUTPUTS AT NO COST
Remote activations at no cost are possible if the control panel is provided with GSM module with a valid SIM Card and the GSM
answer machine function is enabled.
This function uses the Caller ID of the calling telephones to activate programmable commandable outputs rapidly. During programming,
a commandable output is assigned to a mobile telephone number stored on the control panel (one of those which are used to send
alarms or other functions).
IMPORTANT!
One telephone number may control multiple outputs. One output may be controlled by multiple telephone
numbers.
The operating principle is:
1. Call the GSM number of the control panel from a registered telephone number.
2. Hang up within three rings to avoid charges.
3. All the assigned commandable outputs will be activated: the pulse outputs will be operated for approximately one second (e.g. to
open the gate), the switchable or toggle commands will change state and remain active until they are deactivated by sending a
command in a text message.
4. To confirm reception of the command, the control panel will call back the number which made the call for a few seconds. Do not
reply to avoid changing the cost to the SIM Card of the control panel.
6.4
REMOTE CONTROL WITH GUIDED VOICE MENU
The remote control call can be made from a landline with tone keypad (DTMF) or a mobile phone. The PSTN or GSM answer machine
and remote disarming functions must be enabled to uses all functions (see
User Manual
).
IMPORTANT!
Check that the telephone in use does not make anonymous calls because the control panel must be able to
recognise the caller. Using a mobile phone, the function will allows to enable anonymous calls can be enabled in a specific
menu. The menu is telephone-specific. The most common names are:
“Show ID”
, “
Show my number to”
,
“Show personal
number”
. Check the settings in case of problems and try again.
Remote controls can be used to: arm partitions, disarm partitions, switch commandable outputs, activate environmental listening,
isolate and include inputs, query system status.
The system status summary sends vocal messages related to: armed partitions, generic events present in the Event Log, no power
indication, inefficient battery indication, SIM Card expiry.
No vocal message is generated if all partitions are disarmed and no event is present.
Wrong code or excluded input events are not managed even if stored in memory.
Proceed as follows for remote control:
1. Call the telephone number of the control panel from a landline or mobile phone.
2. Enter the Master code within 10 seconds on the keypad at the prompt. Enter a digit and wait for the confirmation beep before
entering the next one. Enter “#” at the end of the digits.
3. You will hear a welcome message if the entered message is correct. Otherwise, try to enter the code again (up to three attempts).
4. After having been recognised you have a few seconds to enter the menu number (see
Table 12 - List of DTMF commands
) and
access the required menu directly. Otherwise, follow the voice menu instructions to access and use the various functions.
5.
Press “
*
“ repeatedly to exit remote control.
IMPORTANT!
In remote control mode, the
*
(asterisk) will go back to the previous menu.
Summary of Contents for MP500/16
Page 139: ...MP500 4N 8 16 Programming 139 ...