62
MP500/4N-8-16 Programming
4.18.9.1
Programming procedure
Proceed as follows to program the IDP/IP parameters:
1. Enter
<Installer code>
, press
, then
and finally
repeatedly until TELEPHONE
DIALLER appears.
2. Press
and then
several times until IDP/IP PARAM. appears.
3. Press
.
4. Press
. Enter the REM.CTRL CODE setting on the keypad and press
to confirm.
5. Press
.
6. Press
. Enter the CODE RECEIVER parameter setting on the keypad and press
to
confirm.
7. Press
.
8. Press
. Enter the SYSTEM CODE setting on the keypad and press
to confirm.
9. Press
.
10. Press
. Enter the ENABLE ENCRYPT. parameter setting on the keypad and press
to
confirm.
11. Press
.
12. Press
. Enter the ENCRYPTION KEY setting on the keypad and press
to confirm.
13. Press
.
14. Press
. Enter the TIME STAMP setting on the keypad and press
to confirm.
15. Press
repeatedly to exit from the menu.
4.18.10
PSTN Line Test
The MP500/xx control panels can be programmed to check for the dial tone and ensure that the connection is working perfectly. A
“Telephone fault” event is generated if it is not. This event is generated after three consecutive unsuccessful tests.
Note:
It is advisable to enable the Tone Line Check function as well if the PSTN Line Test function is enabled.
IMPORTANT!
If the control panel is the first device on the telephone line, as recommended, the line test will interrupt any
telephone calls in progress. This is because the control panel engages the line for a few seconds for each test.
Possible PSTN line test settings are:
Disable
: the dial tone is not checked (this choice is only recommended if the control panel is connected to a PABX extension line).
24h
: the dial tone is checked every 15 minutes even if the system is disarmed. This function is EN50131 grade 2 compliant.
System ON
: the dial tone is checked every 15 minutes only if all configured partitions are armed.
ATS4
: (function available but not necessary on MP500/4N control panel) the connection between the ILT500-N interface and the
ATS4 external communicator is checked. A telephone fault event is generated within no longer than 90 seconds if there is no
connection. Having an ATS4 communicator connected and working is mandatory for EN50131 grade 3 compliance. The dial tone
is checked by the ATS4 communicator. This function is EN50131 grade 3 compliant.
UT00:
INSTALLER
TELEPHONE
DIALER
TELEPHONE
DIALER
IDP/IP PARAM.
IDP/IP PARAM.
REM.CTRL CODE
IDP/IP PARAM.
CODE RECEIVER
IDP/IP PARAM.
SYSTEM CODE
PARAMETRI IDP/IP
ENABLE ENCRYPT.
IDP/IP PARAM.
ENCRYPTION KEY
IDP/IP PARAM.
TIME STAMP