Appendix B: Transmitter Installation
iConnect
Installation Manual
91
Registration Procedure
The EL-4607 must identify itself to the iConnect Control System as follows:
1.
Set the system to registration mode.
•
Go to the main menu and select [9]>[1]>[1] (Programming > Devices > Zones)
•
Select a zone and press '
√ʹ.
2.
Open the detector housing.
3.
Remove the divider separating the battery from the contacts on the battery holder. The detector will send a
transmission. If the transmission is successfully received by the system it will play a confirmation sound. If no
confirmation sound is heard send another transmission by pressing and releasing the tamper switch of the
device.
Due to the occurrence of voltage delay in lithium batteries that have been in storage, the
batteries may initially appear to be dead. In this case, leave the unit in Test mode for a few
minutes until the battery voltage level is stabilized.
4.
As soon as 'Save?' appears press '
√ʹ.
Parameter Settings
As a 2-Way detector, the EL-4607 parameters can be modified only from the iConnect Control System.
The parameter settings can be defined as follows:
1.
Go to the main menu and select [9]>[1]>[1]>[11] (Programming > Devices > Zones>Sensor Par.)
2.
Select Sensitivity and define the parameter accordingly (1 – 100); 1 being the lowest, 100 the highest.
3.
Press'
√ʹ to confirm.
Installation Procedure
After the detector has been registered, mount the unit as follows:
Before permanently mounting the unit, test the detector from the exact mounting position. If
necessary, relocate the detector to a better position.
1.
Open the detector housing.
2.
Remove the PCB by pressing the PCB release tab.
When handling the PCB, do not apply pressure on the antenna.
3.
Mount the back cover using two screws and replace the PCB. Use ISO 7050 (ST3.5 x 22) or similar countersunk
screws so that the screw head will not touch the PCB.
Figure B- 21: Mounting Screw Position
Figure B- 22: Rear Tamper Release
The upper screw is also used for back tamper. When the detector is removed from the wall,
the screw causes the tamper release to break away from the back cover and the rear tamper
switch is released.
4.
Test the detector, making certain that the LED is lit during transmission.
5.
Close the front cover of the detector.
Testing the Vibration Detector
Once you have mounted the detector, test the detector’s sensitivity, as follows:
1.
With the tamper switch open, strike the protected door or window at the furthest point away from the detector
with a screwdriver handle or cushioned tool; the LED color indicates the sensitivity level of the detector. Refer
to following table:
Summary of Contents for iconnect
Page 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Page 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Page 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Page 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Page 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Page 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...