Appendix B: Transmitter Installation
iConnect
Installation Manual
107
Registration Procedure
The EL-4764 must identify itself to the iConnect Control System as follows:
1.
Set the system to registration mode.
•
Go to the main menu and select [9]>[1]>[1] (Programming > Devices > Zones)
•
Select a zone and press '
√ʹ
2.
Ensure batteries are in place (as per Installation instructions above). The detector will send a transmission. If the
transmission is successfully received by the system it will play a confirmation sound. If no confirmation sound
is heard, send another transmission by pressing and releasing the tamper switch of the device.
3.
After the detector is successfully registered the display shows: Save? Press '
√ʹ to confirm.
TEST/HUSH POWER SERVICE ALARM ALARM VENT
SENSOR VENT
Figure B- 48: CO2 detector registration procedure
LED & Buzzer Indication
Table B-8: LED & Buzzer Indication (EL-4764)
Led Color
LED Status
Buzzer
Meaning
Green (Power)
Flashing On and Off every 30
seconds
Normal condition
RED (Alarm)
Flashing
Sequential Alarm Sound
Alarm
Orange (service)
Flashing On and Off
Sequential Alarm Sound
Internal self test fail -
service required
All LED's
Flashing
3 beeps for a period of 3
seconds
Test mode
Due to the occurrence of voltage delay in lithium batteries that have been in storage, the
batteries may initially appear to be dead. In this case, leave the unit in Test mode for a few
minutes until the battery voltage level is stabilized.
Testing And Resetting Your Detector
A green power light indicates that power is supplied. To test the detector, press the Test button. The detector will beep
intermittently and the three LEDs will flash. Release the Test button. The beep and the three LEDs will stop and the green
LED remains on or flashes every 60 seconds.
Muting Your Detector
You can partially mute the detector in an event of alarm by pressing the Test Button. The Red LED will continue to flash
and a short beep will be heard every 16 seconds.
Detector Malfunctioning
A malfunctioning unit is indicated by beep-sounding on and off sequentially, i.e., beeping for 3 seconds with 3 seconds
delay between two beeps. If this occurs, remove the batteries from the unit for 10 seconds and then install them again.
Should the unit again beep intermittently, DO NOT use this detector. Send the malfunctioning unit to the manufacturer
for servicing.
Taking Care Of Your Detector
You have to maintain the detector to ensure proper operation:
1.
Use a vacuum cleaner to clean the air vents occasionally to keep them free of dust.
2.
Press the Test button on your detector to test its operation once every week.
Summary of Contents for iconnect
Page 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Page 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Page 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Page 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Page 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Page 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...