7 Devices
iConnect Installation Manual
38
7.3.4.
Bell (Siren)
Each zone can be programmed to activate the siren when triggered or to generate a silent alarm where only a message is
sent to the central station.
To program the Bell option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select Bell [#05]; the zone’s current Bell setting is displayed.
4.
Select either Enabled or Disabled.
Fire zones always activate the siren regardless of what is programmed for this option.
If the bell is disabled for Panic zones, this also disables all forms of alarm
indication from the on-board keypad in the event of a Panic alarm.
If the Bell option is enabled for Environmental or Flood zones, the system
sounds trouble tones from the keypad.
7.3.5.
Chime
When Chime is enabled, triggering the zone when the system is disarmed causes the internal siren to chime.
To program the Chime option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select Chime [#06]; the zone’s current Chime setting is displayed.
4.
Select either Enabled or Disabled.
7.3.6.
Force Arm
Force arming enables you to arm the system when the system is not ready. For example, a door that is protected by a
magnetic contact is open. You may arm the system on condition that the zone is defined as Force Arm enabled. This
door must be closed by the end of the Exit delay otherwise an alarm is generated. If the magnetic contact’s zone is
defined as Force Arm disabled, the system will not be ready to arm until you close the door.
To program the Force Arm option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select Force Arm [#07]; the zone’s current Force Arm setting is displayed.
4.
Select either Enabled or Disabled.
For the Force Arm feature to function, you must also enable Force Arming in System
Options -- see p. 46,
9.3.1 Forced Arm.
7.3.7.
Swinger
A zone defined as Swinger enabled can generate only a limited number of alarms during a specific time period. The
Swinger setting is defined in System Options – see p.46,
9.1 Swinger Setting.
To program the Swinger option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select Swinger [#08]; the zone’s current Swinger setting is displayed.
4.
Select either Enabled or Disabled.
Do not enable the Swinger option for zones that are always active (Panic, Medical
Emergency, Fire, 24-hr, Gas, Flood and Environmental zones).
7.3.8.
CMS (Central Monitoring Station) Reporting
There is an option to enable or disable central monitoring station reporting for each burglary zone specifically. If
enabled, the alarms are reported in the ordinary way, i.e. after the wireless siren delay; if disabled, alarms from this
zone are not reported to the Central Station.
Summary of Contents for iconnect
Page 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Page 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Page 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Page 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Page 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Page 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...