Appendix B: Transmitter Installation
iConnect Installation Manual
88
Due to the occurrence of voltage delay in lithium batteries that have been in storage, the
batteries may initially appear to be dead. In this case, leave the unit in Test mode for a few
minutes until the battery voltage level is stabilized.
4.
As soon as 'Save?' appears press '
√ʹ.
Parameter Settings
As a 2-Way detector, the EL-4601DZ parameters can be modified only from the iConnect Control System.
The parameter settings can be defined as follows:
1.
Go to the main menu and select [9]>[1]>[1]>[11] (Programming > Devices > Zones>Sensor Par.)
2.
Select the Sensor Type (Magnetic, Universal or Ma Universal)
3.
Define Second Zone (1-32) for dual Ma Universal configuration.
By default the EL-4601DZ is registered as a Magnetic Contact. The Universal Transmitter
can function in the same zone or can be assigned to a separate zone. If assigned to a separate
zone any receiver already assigned to the selected zone will be deleted. For dual
configuration each zone should be configured exclusively.
4.
Press'
√ʹ to confirm.
Installation Procedure
Once the detector has been registered mount the detector as follows:
Before permanently mounting the unit, test the transmitter from the exact mounting
position. If necessary, improve the position of the transmitter. The alarm is generated by
magnet removal at 24 (+/- 0.5) mm and is cleared by magnet approach at 22 (+/- 0.5) mm
1.
Open the detector housing.
2.
Remove the PCB by pressing the PCB release tab.
When handling the PCB, do not apply pressure on the antenna.
3.
Mount the back cover using two screws and replace the PCB. Use ISO 7050 (ST3.5 x 22) or similar countersunk
screws so that the screw head will not touch the PCB.
Figure B- 15: Mounting Screw Position
Figure B- 16: Rear Tamper Release
The upper screw is also used for back tamper. When the detector is removed from the wall,
the screw causes the tamper release to break away from the back cover and the rear tamper
switch is released.
4.
Knockout the wiring hole in the back cover.
5.
Thread the wires through the wiring hole.
6.
Connect the terminal block.
7.
Test the transmitter, making certain that the LED is lit during transmission.
8.
Open the magnet housing.
9.
Mount the back cover of the magnet using two screws.
Make sure that the guideline on the magnet is correctly aligned with the guideline on the
transmitter. Do not install the magnet further than 1cm from the transmitter.
10.
Test the transmitter, making certain that the LED is lit when opening the door/window and again when closing.
11.
Close the front covers of the transmitter and the magnet.
Summary of Contents for iconnect
Page 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Page 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Page 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Page 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Page 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Page 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...