Appendix B: Transmitter Installation
iConnect Installation Manual
116
Attach the tamper hole to the wall during mounting and attach the tamper connector and lead to the main panel.
Set the Tamper dipswitch SW1 according to your tamper protection preferences, see Tamper Bypass section, below.
Tamper Bypass
The circuit board provides an option to bypass the front and back tamper, as shown in the following table:
Table B-10: Tamper Bypass Settings
Dipswitch SW1
Setting
Description
ON
Tamper bypass is in effect. Use this setting
during programming and if no back tamper
has been connected.
OFF
(Default): No tamper bypass is in effect. Use
this option when back tamper is connected
to the system.
Choosing the Mounting Location
Before you mount the 2-Way Wireless I/O Expander Module plastic unit, study the premises carefully for the best
possible coverage and yet easily accessible to devices and accessories. Consider the following before mounting the 2-Way
Wireless I/O Expander Module plastic unit:
•
Centrality of location among all the detection devices and transmitters
•
Proximity to an uninterrupted AC power supply
•
Distance from sources of interference, such as direct heat sources, electrical noise such as computers,
televisions etc., large metal objects, which may shield the transmission antenna
•
Dryness
Mounting the I/O Expander Module
The 2-Way Wireless I/O Expander module unit consists of back and front panels and features plastic click-mounting for
all internal components.
1.
Separate the sub-assemblies by pressing the circular locking plastic brackets on either side to release the front cover
(see below).
Figure B- 57: Box clip release
2.
Remove the circuit board and if required open knock outs for the entry of input and power wires.
3.
Hold the mounting bracket against the wall as a template and mark the locations for the mounting holes (4
mounting holes and an additional optional hole for securing the tamper protection bracket item).
Figure B- 58: Mounting screw template
4.
Drill the desired mounting holes and place the screw anchors.
Do not permanently mount the plastic unit at this point of the installation
Summary of Contents for iconnect
Page 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Page 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Page 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Page 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Page 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Page 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...