To program the Guard Code Control option:
1.
From the Programming menu, select System Options, Guard Code CT, Guard Code Ctr. [94221].
2.
Select Enabled or Disabled.
Clear Users function also clears the Guard Code even if the Guard Code Control is set as
Enabled.
9.8.2.
Guard Code Report
Guard Code Report option allows reporting of the Arm/Disarm events (including Disarm after an Alarm) to the Central
Station even if the Arm/Disarm event group reporting is disabled – see p. 64,
10.9.1 Event Reporting.
When the Guard Code Report option is enabled, the Guard Code option [9408] must be
disabled.
To Activate the Guard Code Control option:
1.
From the Programming menu, select System Options, Guard Code, Guard Code CT, Guard Code Rep [94222].
2.
Select Enabled or Disabled.
9.9.
"No Arm" Indication
The "No Arm" indication is a feature designed to inform the central station that the system has not been armed for a
specified period of time.
To define the "No Arm" indication interval:
1.
From the Programming menu, select System Options, No Arm Ind. [9409].
2.
Select 1 Week, 2 Weeks, 3 Weeks, 4 Weeks or Disabled.
The No Arm event message is an unclassified event. This means that it does not belong to
any event group. If the No Arm option is programmed with any option other than
"Disabled", the event message will be sent.
9.10.
Jamming Detection
The system is able to detect RF Jamming that is usually caused by an intruder attempting to compromise the security
system.
To program the Jamming Detection setting:
1.
From the Programming menu, select System Options, Jamming Det. [9410].
2.
Select Enabled or Disabled.
9.11.
"No Motion" Time
The No Motion feature is designed to monitor the activity of disabled or elderly people. If a detector defined as "No
Motion" (see p. 37,
7.3.1 Zone Type) has not detected within a pre-defined period of time, a No Motion event message is
sent to the central station.
To program the No Motion time:
1.
From the Programming menu, select System Options, No Motion [9411].
2.
Enter the No Motion time value between 00:00 and 72:00. To disable the No Motion feature, enter 00:00. Press '
√ʹ.
9.12.
Microphone/Speaker Options
In addition to the built-in microphone and speaker, the iConnect Control System Control System supports an
external microphone/speaker unit called Interphone. The Microphone/Speaker option allows you to choose which
microphone and speaker are in use. You can choose one mic./speaker (internal or external) to function exclusively or
both may function simultaneously.
To program the Microphone/Speaker option:
1.
From the Programming menu, select System Options, Mic./Speaker [9412].
2.
Select Internal, External or Internal & External.
Summary of Contents for iconnect
Page 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Page 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Page 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Page 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Page 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Page 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...