2 System Installation
iConnect
Installation Manual
9
2.2.2.
Step 2: Selecting Language and Defaults
The Control System supports several languages. Upon power-up the control system automatically opens the language
and default settings menu. Language and defaults settings must be defined before any configuration parameters are set
or any transmitters registered.
To define language and defaults settings:
1.
Press '
√ʹ.
2.
Enter your Installer code (the default Installer code is 1111).
3.
From the Programming menu, select Devices [971] (Programming, Initialize, Init. All).
4.
Select the default setting and press '
√ʹ.
5.
Select a language (Voice + LCD display) and press '
√ʹ.
6.
Press '
√ʹ once more to restart the Con
trol System.
2.2.3.
Step 3 – Establishing an RF Wireless Network
In order to provide the best possible installation environment you need to establish an effective RF wireless network.
RF wireless network establishment should be performed prior to any wireless device allocation in order to select the
best RF channel according to the levels of background
ʺnoiseʺ in the installation environment. This procedure helps the
devices, once registered, to effectively deal with any high levels of background noise that may be generated by
additional appliances operating at similar frequencies in the installation area.
To establish an RF wireless network:
1.
Press '
√ʹ.
2.
Enter your Installer code.
3.
From the Programming menu, select Devices [9191] (Programming, Devices, RF Network Establishment).
4.
Press '
√ʹ. The Control System scans several RF channels and selects the channel with lower ʺnoise levelʺ.
5.
When Save? is displayed on the Control System’s LCD, press '
√ʹ.
Network establishment must be performed prior to wireless device allocation.
If required, after the initial network is established, you can calibrate the receiver again only after deleting
the network by selecting [9193] (Programming, Devices, RF Network, Delete Network).
2.2.4.
Step 4 – Registering Transmitters
For the Control System to recognize a device, its transmitter must be registered. In general terms, transmitter
registration means sending two transmissions from a device when the Control System is in Registration mode.
To register a device:
1.
Press '
√ʹ.
2.
Enter your Installer code.
3.
Enter [91] (Programming, Devices) to enter the Devices menu.
4.
Press the menu navigation keys (
/
), until the type of device you want to register appears on the LCD display
(e.g. Zones or Keypads).
5.
Press '
√ʹ.
6.
Press the menu navigation keys (
/
), until the exact device you want to register appears on the LCD display
(e.g. Zone 3 or Keypad 2).
7.
Press '
√ʹ. If a device has not been registered at the chosen location, the Control System initiates Registration mode.
During Registration mode, the system waits for two transmissions from the device.
If a device has already been registered at the selected location, or in another location, the system will not
initiate Registration mode.
8.
Send two transmissions from the device – refer to each device’s installation instructions in Appendix B for
further details.
9.
When Save? is displayed on the Control System’s LCD, press '
√ʹ.
The display automatically switches to the next option for that device. For example, pressing '
√ʹ to
confirm Zone registration automatically moves you to the Zone Type option.
10.
Continue entering other parameters for the chosen device.
Summary of Contents for iconnect
Page 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Page 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Page 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Page 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Page 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Page 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...