9.7.3.
Polarity
You can determine the polarity of the PGM output from the following two options:
•
Active High: The output is normally off and is switched on when activated.
•
Active Low: The output is normally on and is switched off when activated.
To program the Polarity:
1.
From the Programming menu, select System Options, PGM Options [9407].
2.
Select a PGM Output.
3.
Select Polarity [#3].
4.
Select Active High or Active Low.
9.7.4.
PGM Cut-off
The PGM Cut-off is the duration for which the PGM is activated. Certain Output Trigger types are deactivated after the
PGM Cut-off time has expired– see,
9.7.2, Output Type. For those Output Trigger types that are not affected by the
PGM Cut-off, there is no need to program this option.
If, for example, Output Trigger option is set to Full Arm, and PGM Cut-off time is 060 seconds; then PGM is activated
by Full Arming and deactivated by disarming or by PGM Cut-off Time, whichever comes first. If this option is set to
"000" (Continuous activation), PGM is activated by Full Arming, and deactivated by disarming.
To program the PGM Cut-off time:
1.
From the Programming menu, select System Options, PGM Options [9407].
2.
Select a PGM Output.
3.
Select PGM Cut-off [#4].
4.
Enter a PGM Cut-off time (001-255 seconds or 000 for continuous activation), then press '
√ʹ.
9.8.
Guard Code
Guard Code is an option that allows a security guard to check the premises in case of an alarm and to perform basic
functions such as view log etc.
After two minutes since an alarm occurs, the Guard Code becomes active and the security guard can enter the premises
and disarm the system using this code. Installer codes authorization also extends to allow arming and disarming.
Guard Code is active within five minutes since the system is armed. After five minutes, the Guard code is revoked, and
the installer code regular authorization is restored.
Guard code is also active when the system is disarmed.
When the Guard Code option is enabled, the Guard Code Control [94221] and Guard code
report [94222] options must be disabled.
To program the Guard Code:
1.
From the Programming menu, select System Options, Guard Code. [9408].
2.
Select Enabled or Disabled.
3.
Edit the User Code 31 (see p. 22,
4.4.1 Editing User Codes).
When the Guard Code is disabled, it is not valid even if programmed with a value other
than 0000.
9.8.1.
Guard Code Control
Guard Code Control option sets the Guard control value based on account #1, but in reversed order (e.g., the account #1
is set to 88881234, then the Guard Code is set to 4321).
When the Guard Code Control option is enabled, the Guard Code option [9408] must be
disabled.
The installer may use hex digits in the account number; the Guard Code will then be set to
0000.
If the automatically calculated Guard Code is the same number as an existing user code, it
will be set to 0000.
Summary of Contents for iconnect
Page 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Page 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Page 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Page 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Page 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Page 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...