Appendix B: Transmitter Installation
iConnect
Installation Manual
121
EL-4727 Wireless LCD Keypad
Frequency 868* or 433MHz
Power : 4x1.5V Lithium AA batteries
Current consumption : up to 100mA (transmission),
50µA (standby)
Operating temperature : 0°C to 60°C (32°F to 140°F)
Dimensions: 214 x 110 x 35mm
*Complies with EN-50131 2-6 Grade 2 Class II Power Supply Type C
EL- 4762 Gas Leak Detector
Frequency: 868* or 433MHz
Power: AC120V/AC230V (model dependant)
Signal Volume: Approx. 85 dB at a distance of 3 meters
Operating Temperature: 0°C to 40°C (32°F to 122°F)
Storage Temperature: -20°C to 60°C (-4°F to 140°F)
Dimensions: 140 X 80 X 49 mm
*Complies with EN-50131 2-6 Grade 2 Class II Power Supply Type C
EL- 4764 Carbon Monoxide Detector
Frequency: 868* or 433MHz
Power: 2 x CR 123, 3V Lithium Battery
Current Consumption: 20 µA (standby), 30mA (Alarm)
Signal Volume: Approx. 85 dB at a distance of 3 meters
Operating Temperature: 4°C to 38°C (39°F to 100°F)
Storage Temperature: -20°C to 60°C (-4°F to 140°F)
Dimensions: 140 X 80 X 49 mm
*Complies with EN-50131 2-6 Grade 2 Class II Power Supply Type C
EL- 4761 Flood Detector
Frequency: 868* or 433MHz
Power: 3.6VDC ½ AA Lithium Battery
Current Consumption: 25mA (transmission),
40
µ
A (standby)
RFI Immunity: According to EN 50130-4
Operating Temperature: 0-60°C
Dimensions: 65 x 30 x 25mm
*Complies with EN-50131 2-6 Grade 2 Class II Power Supply Type C
EL-4723 Indoor Siren
Frequency: 868* or 433MHz
Power: 4 X CR123, 3V Lithium Battery (2 batteries for the Radio
Transceiver, 2 batteries for the Speaker)
Current Consumption: 25mA (transmission), 40
µ
A (standby)
Siren Output: Approx.
85
dB @ 1m
Operating Temperature: -25°C to 60°C (-4°F to 140° F)
Dimensions: Ø183 x 51 mm
*Complies with EN-50131 2-6 Grade 2 Class II Power Supply Type C
EL-4726 Outdoor Siren/Strobe
Frequency: 868* or 433MHz
Power: 4 X CR123, 3V Lithium Battery (2 batteries for the Radio
Transceiver, 2 batteries for the Speaker)
Current Consumption: 25mA (transmission), 40
µ
A (standby)
Siren Output: Approx. 105dB @ 1m
Operating Temperature: -25°C to 60°C (-4°F to 140° F)
Dimensions: 340 x 222 x 73mm
*Complies with EN-50131 2-6 Grade 2 Class II Power Supply Type C
EL- 4770 I/O Expander Module
Frequency: 868* or 433MHz
Power Input: AC/DC Adaptor 100-240V,50/60Hz/14.4VDC,1.5A
Current Consumption: Typical: 40 mA; 65mA maximum
Rechargeable Standby Battery: 12VDC±2VDC up to 7Ah, typical
Auxiliary Power Outputs: 12VDC@1000mA, maximum (from all
AUX terminals)
PGM Relay Output Dry Contact Rating: Dry contact –
1A@30VDC,0.5A@25VDC
Number of Zones: 8
Zone Loop Type: N.C. / N.O. / E.O.L. (Programmed at the Control
System)
Tamper Protection: Front cover and back tamper (N.C.)
RF immunity: According to EN50130-4
Operating temperature : -10°C to 40°C (14°F to 104°F)
Storage temperature : -20°C to 50°C (-4°F to 122°F)
Usage: Indoor
Dimensions (Plastic Case): 290 x 254 x 97 mm (11.2 x 9.7 x 3.6 inch)
*Complies with EN-50131 2-6 Grade 2 Class II Power Supply Type C
Lithium Batteries
Fire, explosion and severe burn hazard!
When handling lithium batteries follow the listed precautions:
•
Do not recharge.
•
Do not deform or disassemble.
•
Do not heat above 212°F (100°C) or incinerate.
Due to the occurrence of voltage delay in lithium batteries that
have been in storage, the batteries may initially appear to be
dead. In this case, leave the unit in Test mode or Radio mode
for a few minutes until the battery voltage level is stabilized.
!
Summary of Contents for iconnect
Page 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Page 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Page 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Page 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Page 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Page 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...