Appendix B: Transmitter Installation
iConnect
Installation Manual
83
Installation Procedure
To install PIR detectors:
Before permanently mounting the detector, test the transmitter from the exact mounting
position. If necessary, improve the position of the transmitter. The recommended height is
2.2m (6.6 ft).
1.
If the unit is screwed together, unscrew the casing back.
2.
Knock out the mounting holes of the mounting bracket and attach it to the wall, as appropriate.
Figure B- 3: Mounting Screw Position
Figure B- 4: Rear Tamper Release
3.
To use the rear tamper switch, insert a screw into the rear tamper mounting hole located in the lower center of the
bracket. When the bracket is removed from the wall, the screw causes the tamper release to break away from
the bracket and the rear tamper switch is released
4.
Attach the screw provided in the detector kit to the bottom of the mounting bracket.
Operation Modes
Warm-up Time
The detector will need to warm up for the first 90 seconds after applying power.
Walk Test Mode
A walk test is performed in order to determine the lens coverage pattern of the detector. Walk Test mode cancels the
delay time between detections, enabling you to perform an efficient walk test.
To walk test the detector:
1.
Set the iConnect Control System to Walk test mode (Quick key 7>03>4).
2.
Walk across the scope of the detector according to the detection pattern selected.
3.
Confirm that the LED activates and deactivates accordingly. Wait for ten seconds after each detection before
continuing the test.
4.
After completing the walk test set the system to normal operation mode.
To test the detector camera:
1.
Set the iConnect Control System to camera test mode (Quick key 7>03>5). Confirm with '
√ʹ.
2.
If more than one PIR camera zone is defined, select a defined zone and press '
√ʹ.
3.
In the displayed: SNAPSHOTS, choose the number (1-9) of snapshots to be taken and press '
√ʹ to transmit the
snapshots.
LED Indication
The LED indicator is lit every time a transmission is made. The LED can be enabled / disabled by programming.
Battery Replacement
In case of a low battery (2.5VDC or less), the detector low battery condition is reported to the system and low battery
message is displayed.
To replace the battery:
1.
Unscrew the casing back.
2.
Remove the spent batteries and replace them.
3.
Re-attach the casing front and remount unit.
Summary of Contents for iconnect
Page 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Page 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Page 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Page 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Page 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Page 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...