V&T Technologies Co., Ltd.
http://www.ecodrivecn.com
Chapter 5 List of Parameters
43
Chapter 5 List of Parameters
Meanings of Each Item in Function Code Parameter Table
Item
M e a n i n g s
Function code
number
The number of function code, such as P0.00
Function code
name
The name of function code, which explains the function code’s meanings.
Factory setting
Restore the settings of the function code after the product is delivered (see P0.01).
Setting range
The value from minimum value to maximum value that can be set to this function code.
Unit
V: Voltage; A: Current; ºC: Celsius degree;
Ω
: Ohm; mH: Milli-henry; rpm: Rotating speed; %:
Percentage; bps: baud rate; Hz, kHz: Frequency; ms, s, min, h, kh: Time; kW: Power; /: No unit
Property
○: This function code can be changed during operation; ×: This function code can only be changed
during stopping status; *: The setting of this function code is read-only and cannot be changed.
Function code
selection
Function code parameter setting list
User setting
Used for recording parameters by user
5.1 List of Basic Menu Function Codes
Function
code
number
Function code
name
Factory
setting
Setting range
Unit
Property
Function code selection
User
setting
Group P0 Basic Function Parameter
P0.00
User password
0000
0 ~FFFF
/
○
0000: No password;
Other: Password protection
P0.01
Function code
protection
0
0 ~ 5
/
×
0: All the parameters can be
modified;
1: All the parameters cannot be
modified;
2: Restore parameters in zone P
to factory settings;
3: Restore parameters in zone P
to factory settings; (except for P9
group)
4: Recover the parameters in
zone P and zone A to factory
settings;
5: Recover all the parameters to
factory settings. (except for d
group)
P0.02
Function code
display
0
0 ~ 3
/
○
0: Basic menu mode
1: Fast menu mode
2: Menu mode of
non-leave-factory setting value
function codes;
3: Menu mode of last changed
10 function codes;
P0.03
Control operation
mode
0
0 ~ 7
/
×
Vector control 1 without
encoder speed feedback:
0: Process open loop control;
1: Analog value feedback
process close loop control;
2: Single phase pulse feedback