V&T Technologies Co., Ltd.
http://www.ecodrivecn.com
Chapter 1 Introduction to V5
−
H Series Inverter
3
V5
−
H
−4T
□□□
L Three-phase 400V Variable torque/light-duty application
Power (kW)
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
Motor
power (kW)
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
Output
Voltage (V)
Three-phase 0 to rated input voltage
Rated current (A) 3.3
5.0
7.5
11
17
22
30
37
44
56
72
91
110
142 176
Overload
capability
115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)
Input
Rated
voltage/frequency
Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage
fluctuation range
323V ~ 528V; Voltage unbalancedness:
≤
3%; allowable frequency fluctuation: ±5%
Rated current (A) 5.6
8.1
13.5 19.5
26
39
50.3
60
69.3
86
104
124
150
190 235
Braking unit
Built-in as standard
Built-in as option
Protection class
IP20
Cooling mode
Self-cooling
Forced air convection cooling
Power (kW)
110
132
160
185
200
220
250
280
315
355
400
450
500
560
Motor
power (kW)
110
132
160
185
200
220
250
280
315
355
400
450
500
560
Output
Voltage (V)
Three-phase 0 to rated input voltage
Rated current (A) 210 253 304 350 380 426 470 520 600 650 690 775 860 950
Overload
capability
115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)
Input
Rated
voltage/frequency
Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage
range
323V ~ 528V; Voltage unbalancedness
≤
3%; allowable frequency fluctuation: ±5%
Rated current (A) 196
*
232
*
282
*
326
*
352
*
385
*
437
*
491
*
580
*
624
*
670
*
755
*
840* 920*
Braking unit
External braking unit needed
Protection class
IP20
Cooling mode
Forced air convection cooling
*V5
−
H
−4T
110L and above products are equipped with external DC reactor as standard.
V5
−
H
−2T
□□□
G Three-phase 200V Constant torque/heavy-duty application
Power (kW)
0.4
0.75
1.5
2.2
Motor
power (kW)
0.4
0.75
1.5
2.2
Output
Voltage (V)
Three-phase 0 to rated input voltage
Rated current (A)
3
5
7.5
10
Overload capability
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes
(inverse time lag feature)
Input
Rated
voltage/frequency
Three-phase or single-phase 200V~240V; 50Hz/60Hz
Allowable voltage
range
180V ~ 260V; Voltage unbalancedness
≤
3%; allowable frequency fluctuation: ±5%
Rated current (A)
3.8
5.5
8.3
12
Braking unit
Built-in as standard
Protection class
IP20
Cooling mode
Self-cooling
Forced air convection cooling