V&T Technologies Co., Ltd.
http://www.ecodrivecn.com
Chapter 6 Parameter Description
80
Multi-functional input terminal definition table:
SN
Function definition
SN
Function definition
0
Jog forward
27
Shutdown via terminal with DC braking 2
1
Jog reverse
28
Counter trigger input
2
Forward (FWD)
29
Counter trigger reset
3
Reverse (REV)
30~46
Reserved
4
Three-wire operation control
47
PG feedback closed loop control single
phase pulse input
5
Pulse frequency DI input (only available for
X7/DI terminal)
48
Command switching to operation panel
6
Multi-section digital voltage terminal 1
49
Command switching to terminal
7
Multi-section digital voltage terminal 2
50
Command switching to host computer
8
Multi-section digital voltage terminal 3
51
Main frequency source close loop and open
loop switching input
9
Multi-section frequency terminal 1
52
Main frequency source switching to digital
10
Multi-section frequency terminal 2
53
Reserved
11
Multi-section frequency terminal 3
54
Main frequency source switching to AI1
12
Multi-section frequency terminal 4
55
Main frequency source switching to AI2
13
Acceleration/deceleration terminal 1
56
Main frequency source switching to AI3
14
Acceleration/deceleration terminal 2
57
Main frequency source switching to DI
15
Digital regulating frequency reset
58
Auxiliary frequency source switching to
disabled
16
Frequency increase instruction
59
Reserved
17
Frequency decrease instruction
60
Auxiliary frequency source switching to AI1
18
Acceleration/deceleration
disable
instruction
61
Auxiliary frequency source switching to AI2
19
External failure input
62
Auxiliary frequency source switching to AI3
20
Terminal failure reset input
63
Auxiliary frequency source switching to DI
21
External interrupt contact input
64
Speed control/torque control switching
22
Inverter running disabled
65
Speed limiting forced to be Pd.06 and Pd.07
23
Shutdown via terminal
66
Zero servo enable terminal
24
Free shutdown via terminal
67
Closed loop output forced to be 0
25
Shutdown via terminal with DC braking 1
68
PID positive or negative function
26
Emergency shutdown 1 (fastest shutdown)
69~98
Reserved
Relevant term explanation:
Terminal Xi: Refers to any of terminal X1, X2, X3, X4, X5, X6 or X7, also called terminal X.
Terminal Yi: Refers to terminal Y1, Y2 or relay also called terminal Y.
Terminal function enabled: Means that terminal Xi has set the function under description. And P7.25
adopts the leave-factory value, the terminal is closed; when the P7.25 adopts the non-leave-factory value,
the terminal is open.
Terminal function disabled: Means that terminal Xi has not set the function under description; or it has set
the function, but when P7.25 adopts the leave-factory value, the terminal is open; or when the P7.25
adopts the non-leave-factory value, the terminal is closed.
The leave-factory setting of terminal Xi (i=1~7) is no function (function code set as 99).
0: Terminal jog forward input
1: Terminal jog reverse input
2: Terminal forward run input (FWD)