7.7.6 REGINT
Interval between checks for network registration and status.
Value in milliseconds: minimum 3000ms, maximum 65535ms (approximately 1 minute).
Factory default: 2000 milliseconds
9876 OPTION REGINT 3000
7.7.7 INP
Interval between checks for SMS messages.
Value in milliseconds: minimum 5000ms, maximum 65535ms (approximately 1 minute).
Factory default: 15000 milliseconds
9876 OPTION INP 15000
7.7.8 REGFAIL
Maximum time to wait for the module to register on a network before giving up and power
cycling the module to try again.
This limit is only observed if an action (call or notification) is required. If no action is pending,
the module will remain powered until an action is required and if the module has still failed to
register the module will be power cycled.
Value in seconds: minimum 60s, maximum 3600s (1 hour).
Factory default: 90 seconds
9876 OPTION REGFAIL 90
7.7.9 REGBOOT
Reboot the radio module if registration has been lost for a period of time.
Value in seconds: minimum 60s, maximum 32767s (approximately 9 hours).
Factory default: 300 seconds
9876 OPTION REGBOOT 300
7.7.10
IDLE
Call disconnect, idle timeout value. Disconnect a call if no data has been received or sent for
a period of time.
Value in seconds: minimum 5s, maximum 65s (approximately 1 minute).
Factory default: 55 seconds
9876 OPTION IDLE 55