MesCom
– Workshop Manual – D6000/i14/V10
© Dycon Ltd 2014
-
59
7.7.35
ICCID
This is a read only command for use with the VIEW OPTION command.
Display the current SIM card ICCID number.
9876 VIEW OPTION ICCID
7.7.36
IMEI
This is a read only command for use with the VIEW OPTION command.
Display the radio module IMEI number.
9876 VIEW OPTION IMEI
7.7.37
APN
Provide APN settings. The MesCom can support 2 APNs if both are set; the MesCom is
unable to attach to the primary APN, the secondary APN will be used. This command can be
used to set both the primary and secondary APNs. The first use will set the primary, the
second use will set the secondary all subsequent uses of the command will set the primary
until the REMOVE keyword is used and the secondary will be removed, and a subsequent
command will then set the secondary.
The primary APN can’t be removed, only over written.
9876 OPTION APN <Access_Point_Name> <username> <password>
Eg.
9876 OPTION APN internet web web
See section 16 for common UK APN settings. Username and password can be left blank but
no more OPTION parameters should follow in the same SMS.
To remove the secondary APN and allow a new secondary APN to be set.
9876 OPTION APN REMOVE
Follow this command with the set command above to set the secondary APN.
7.7.38
ACCOUNT
Set the default access levels and incoming authentication for unknown users and terminal
access. See section 5 for more detail of user settings.
Factory default: na <imei> 1 2 0 na
Where <imei> is the last 4 digits of the IMEI number.
9876 OPTION ACCOUNT <address> <password> <access> <format> <transport> <username>
eg
9876 OPTION ACCOUNT ignored password 2 2 4 username
7.7.39
FACTORY
Set the address of the MesCom configuration server. See section 5 for more detail of user
settings.
Factory default: Dycon configuration manager (
http://www.dyconconfig.com
).
9876 OPTION FACTORY ftp.mydomain.com:21 password 4 0 7 username
Runtime error reports can also be sent to this address - see SYSACT parameters.