MesCom
– Workshop Manual – D6000/i14/V10
© Dycon Ltd 2014
-
57
7.7.27
SYSACT
What action to take for system event level.
The value should be the sum of the options that should be active.
Options
1
– Send high level system events to SMS users (factory default).
2
– Reserved.
4
– Send high level system events to data concentration servers.
8
– High level system events trigger call to host.
16
– Allow bug reports to be sent to the manufacturer.
32
– Reserved.
64
– Reserved.
128
– Reserved.
9876 OPTION SYSACT 9
Also see SYSTEM and FACTORY parameter.
9876 OPTION ERRDELAY 1000
7.7.28
NUMRETRY
Should a call fail, the MesCom will attempt to retry the call. This sets the maximum number
of retry quick attempts before waiting for an extending period.
Minimum 0, maximum 255.
Factory default: 3 retries
9876 OPTION NUMRETRY 10
7.7.29
RETRY
Gap between quick retries.
Value in seconds: minimum 0s, maximum 32767s (approximately 9 hours).
Factory default: 120 seconds (2 minutes)
9876 OPTION RETRY 120
7.7.30
EXTRETRY
Big gap between retries batches.
Value in minutes: minimum 0min, maximum 32767min (approximately 22 days).
Factory default: 120 minutes (2 hours)
9876 OPTION EXTRETRY 60