7.2.16
OPTION
Change a general MesCom setting. See section 7.7 for details of
the parameters available.
Access Level:
Administrator
9876 OPTION <parameterA> <valueA> <parameterB> <valueB> <parameterC> <valueC>
<parameterD> <valueD>
<parameterA> Setting you wish to view.
ALL supported: Yes
<valueA>
Up to 4 parameters
<parameterB> Optional setting you wish to view.
<valueB>
<parameterC> Optional setting you wish to view.
<valueC>
<parameterD> Optional setting you wish to view.
<valueD>
9876 OPTION PSAVE 2 WAKE 120
Enter low power mode when powered by battery, delay
switching to low power for 120 seconds after every
event.
MesCom: OPTION: PSAVE 2 WAKE 120
04/04/12,16:15:25
9876 OPTION ALL …
Allows all general options to be set in one message. It
is not recommended for manual commands. See HELP
OPTION for order of parameters.
Notes
Please Note: All labels MUST contain NO spaces - we suggest underscore
is used instead.
All parameters must be followed by a value; some parameters require more
than one value; all values must be present.
7.2.17
FETCH
Connect to the configuration service and fetch the latest
configuration file.
Access Level:
Administrator
9876 FETCH
ALL supported: No
9876 FETCH
MesCom retrieve a new configuration file without error
MesCom: FETCH Successful 04/04/12,16:15:25
9876 FETCH
MesCom failed to download file or file had errors.
MesCom: FETCH failed 04/04/12,16:15:25
Notes
The command will take a few minutes to complete.