MesCom
– Workshop Manual – D6000/i14/V10
© Dycon Ltd 2014
-
15
5.1.2 Password
Case sensitive.
Each contact has an individual password. To be prefixed to all incoming commands or
authenticate with a remote host. If left blank the system default will be used. From the factory
this default is the last 4 digits of the IMEI number (see label inside the MesCom).
5.1.3 Access Level
What command access level the contact has:
0
Receive - no commands are accepted from this user.
1
Read only
– READ and PASSWORD commands accepted.
2
View
– VIEW, READ and PASSWORD commands accepted.
3
Control
– SWITCH, PULSE, VIEW, READ and PASSWORD commands accepted.
4
Service
– As Administrator but without SWITCH and PULSE commands.
5
Server
– All the features of Administrator but isn’t added to the Admin user count.
6
Administrator
– Access too all commands.
5.1.4 Message Format
The message output format. Care should be taken to select the correct one for the contact.
Hosts will require a specific format and not all formats are suitable for SMS.
0
Do not use - Contact Empty.
1
No Notifications.
2
Standard message
– it is recommended this format is used for SMS.
3, 4, 5, 6 Do not use.
7
Cosm/Xlivey web service.
8, 9
Do not use.
10
Fixed width text
– to align display of many events on screen.
11
HTML
– event will be given as a row in a HTML table.
12
Comma-separated values
– for interpretation by computer.
13
Short message
– without unit name or the time the event took place.
Only Formats 1,2,13 should be used with SMS; all others are for computer systems.
See section 6 for details of the different formats.