Operation
Operating Instructions 911-211-10 - 00.0 - 10/2020
27
Fig. 12: Changing the bobbin (2)
3.
Swivel up the bobbin case retainer (5).
4.
Remove the empty bobbin.
5.
Insert a full bobbin.
Important
Insert the bobbin (4) so that it moves in the opposite direction of the hook
when the thread is pulled out.
6.
Feed the hook thread through slot (8) in the bobbin case retainer.
7.
Pull the hook thread under the tension spring (7).
8.
Pull the hook thread through the guide (6) and place it to the left.
9.
Close the bobbin case retainer (5).
10. Cut off the hook thread at the left edge of the closed bobbin flap.
11. Release the threading mode (2) button.
The hook cover (3) swivels back to the original position.
12. Enter a bobbin change in the software (
(4)
- Bobbin
(5)
- Bobbin case retainer
(6)
- Guide
(7)
- Tension spring
(8)
- Slot
⑧
④
⑤
⑥
⑦