Troubleshooting
114
Operating Instructions 911-211-10 - 00.0 - 10/2020
2355
Stroke position stepper motor overload
• Feed system not moving freely
• Obstacles to the feed motion
• Eliminate sluggishness
• Remove obstacles/adjust the motion
2356
Stroke position stepper motor
overtemperature
• Feed system not moving freely
• Stepper motor faulty
• Control defective
• Eliminate sluggishness
• Replace stepper motor
• Replace control
Machine control
3100
Machine control voltage
• Temporary mains voltage
interruption
• Check mains voltage
3102
Machine voltage in sewing motor
intermediate circuit
• Temporary mains voltage
interruption
• Check mains voltage
3103
Machine voltage in stepper motor
intermediate circuit
• Temporary mains voltage
interruption
• Check mains voltage
3107
Machine temperature
• Ventilation openings closed
• Ventilation grille dirty
• Clean ventilation grille
• Check ventilation openings
3109
Threading mode is switched on
Switch off threading mode
3121
Compressed air is missing, not
sufficient
Turn up air pressure and stabilize
3123
Oil sensor active
Top off the oil
3210
Thread broken
Re-thread the thread
3215
Bobbin empty (remaining thread
counter)
Insert full bobbin
3220
Bobbin empty (remaining thread
counter)
Insert full bobbin
3500
Error in calculating the contour data
• Reload the contour data
• Check the contour data
3501
Target position of the XY clamps
outside the motion limits
Adjust the contour data
3502
Target position of the XY clamps within
the "forbidden areas"
Adjust the contour data
3721
3722
Internal error
• Switch off and on the machine
• Software update
• Notify DA Service
4201
Internal CF card defective
• Switch off and on the machine
• Retrofit/replace control
5301
Program cannot be sewn
Copy program to DAC
Error
code
Description
Troubleshooting
Summary of Contents for 911-211-10
Page 1: ...911 211 10 Operating Instructions...
Page 6: ...Table of Contents 4 Operating Instructions 911 211 10 00 0 10 2020...
Page 10: ...About these instructions 8 Operating Instructions 911 211 10 00 0 10 2020...
Page 34: ...Operation 32 Operating Instructions 911 211 10 00 0 10 2020...
Page 88: ...Programming 86 Operating Instructions 911 211 10 00 0 10 2020...
Page 108: ...Setup 106 Operating Instructions 911 211 10 00 0 10 2020...
Page 110: ...Decommissioning 108 Operating Instructions 911 211 10 00 0 10 2020...
Page 112: ...Disposal 110 Operating Instructions 911 211 10 00 0 10 2020...
Page 133: ......