Programming
60
Operating Instructions 911-211-10 - 00.0 - 10/2020
There are 8 program parameter groups:
Overview of the individual program parameters
Symbol
Parameter group
PP1 - Configuration
General settings
PP2 - Load mode
Load mode and position
PP3 - Deposit mode
Deposit mode and position
PP4 - Soft start
Number of stitches and speed
PP5 - Needle thread monitor
Sensitivity value for the needle thread monitor
PP6 - Thread consumption
Values for determining thread consumption
PP7 - Move:
Contour is moved in a particular direction
PP8 - Scaling:
Size of the contour is changed.
PP1 - Configuration
Symbol
Meaning
Seam name
max. 20 characters
Minimum sewing foot stroke height
(min. = 1.0 .. max. = 10.0; Def. = 5.0 mm )
Sets this as the minimum value of the programmable sewing foot stroke
height so that only this value needs to be adjusted when sewing thicker
materials.
Adjust thread tension
(min. = 10… max. = 200; Def. = 100 %)
The thread tension profile for the entire contour is adjusted accordingly.
A value of 100% means that no adjustments are made.
Adjust empty-run speed
(min. = 10… max. = 200; Def. = 100 %)
The travel speeds are adjusted.
Clamp ID code
Barcode (ID code) of max. 10 characters for performing a safety check
before the start of sewing (the barcode scanner additional equipment must
be activated)
Summary of Contents for 911-211-10
Page 1: ...911 211 10 Operating Instructions...
Page 6: ...Table of Contents 4 Operating Instructions 911 211 10 00 0 10 2020...
Page 10: ...About these instructions 8 Operating Instructions 911 211 10 00 0 10 2020...
Page 34: ...Operation 32 Operating Instructions 911 211 10 00 0 10 2020...
Page 88: ...Programming 86 Operating Instructions 911 211 10 00 0 10 2020...
Page 108: ...Setup 106 Operating Instructions 911 211 10 00 0 10 2020...
Page 110: ...Decommissioning 108 Operating Instructions 911 211 10 00 0 10 2020...
Page 112: ...Disposal 110 Operating Instructions 911 211 10 00 0 10 2020...
Page 133: ......