Programming
Operating Instructions 911-211-10 - 00.0 - 10/2020
63
PP4 - Soft start
Symbol
Meaning
Soft-start stitch count
(min. = 0.. max. = 10; Def. 5)
Soft-start speed
(min. = 100 .. max. = 2000; Def. 300 rpm)
PP5 - Needle thread monitor
(min. = 0 .. max. = 99; Def. 5)
Only active if activated in the machine parameters.
(A higher value makes the needle monitor less sensitive.
99 = Needle thread monitor switched off in this program only.)
PP6 - Thread consumption
Symbol
Meaning
Sewing material thickness
(min. = 0.. max. = 20.0; Def. 0)
The thickness of the sewing material when pressed together.
Adjust thread consumption
(min. = -10.0.. max. = 10.0; Def. 0)
Correction of the calculated values.
PP7 - Move
Symbol
Meaning
X move
(min. = -5.0… max. = 5.0; Def. = 0.0 mm)
Y move
(min. = -5.0… max. = 5.0; Def. = 0.0 mm)