Part Number
Issue
Date
Page
6159937790
12
03/2018
95 / 184
95 (184)
03/2018
The buzzer is activated as follows:
Buzzer
The beep emitted by the buzzer starts when the torque goes over the
Cycle
Start
value, and it increases its signal when approaching the target.
At the end of the tightening operation three more beeps inform the operator of
the end of the operation; if the torque goes over the maximum values, the
beep is repeated at high frequency to indicate the error.
For information on the vibration function, refer to the pa
ragraph “Vibration parameter”.
NOTE:
Vibration is available only for the following Delta Wrench models: TORQUE/ANGLE
MODELS WITH VIBRO and TORQUE/ANGLE MODELS WITH VIBRO AND WLAN RADIO
MODULE.
6.8.1.2
Torque & Angle
This strategy leads the operator in reaching the desired target torque and monitoring the angle.
The
Angle threshold
parameter is the threshold from which to start angle measurement (normally set
to 50% of the
Target Torque
).
The
“
green area
” identifies the OK result area.
If the torque goes over the “
change screw
” value a message is shown on the Delta Wrench display
advising the operator to replace the screw.
Min. Torque
Target Torque
Max. Torque
Min. Angle
Max. Angle
Cycle start
Angle threshold
Torque
Angle
Change screw at