Part Number
Issue
Date
Page
6159937790
12
03/2018
103 / 184
103 (184)
03/2018
6.8.2.3
Residual Peak/Torque
This strategy evaluates the residual torque on a joint as the peak of the torque necessary to rotate the
screw further. The result of this strategy is affected by operator movement; it is important to release
the torque as soon as the screw starts moving.
Specify the
Cycle start
and the
Torque limits
.
Furthermore, it is MANDATORY to set a
Change Screw
value: if the operator goes over this value, a
message is shown on the Delta Wrench display to indicate that the screw must be replaced with a
new one.
The Delta Wrench display background is colored as follows:
Blue
Default color used for Pset execution.
Green
The display turns green if the torque peak is between the minimum and maximum
torque.
Red
The display turns red if the torque peak is below the minimum or over the
maximum torque.
The buzzer is activated as follows:
Buzzer
The beep emitted by the buzzer starts when the torque goes over the
Cycle Start
value.
At the end of the tightening operation three more beeps inform the operator of the
end of the operation; if the result is
Not OK
, the last beep remains active to
indicate the error, and it is reset when either the
OK
or
CL
button is pressed.
Min Torque
Max Torque
Torque Peak
Cycle start
Torque
Time
Change screw at