Part Number
Issue
Date
Page
6159937790
12
03/2018
86 / 184
03/2018
86 (184)
During the test, if the tightening is within the limits (
Max Torque
and
Min Torque
) the vibration is
continuous. In case the tightening is out of the limits (
Max Torque
and
Min Torque
), the vibration is
alternate.
At the end of the test, if the tightening is OK, the Delta Wrench vibrates for three times at a specified
interval (1 second). In case the tightening is NOK, the Delta Wrench vibrates at specified intervals
continuously; stop the vibration with one of the following procedures:
-
do a new tightening;
-
press
OK
→ the Delta Wrench is ready for a new measurement;
-
press
CL
→ the Delta Wrench is out of the Pset.
6.4
Time
End cycle time
This parameter is applied when the torque goes down the cycle start and
reaches the
target torque
value; the default value is 0.1 second.
Minimum value: 0.1 Sec
Maximum value: 5 Sec
This parameter is not used for
residual torque
strategies.
Abort cycle time
This parameter is applied when the torque goes down the cycle start but has not
reached the
target torque
value yet. This allows the operator to release the
torque for a while and recharge during the tightening operation; the default value
is 5 seconds.
Minimum value: 0.1 Sec
Maximum value: 30 Sec
The Delta Wrench ends the tightening operation if the torque drops beneath the
Cycle Start
value for
a longer time than the timer.