Part Number
Issue
Date
Page
6159937790
12
03/2018
81 / 184
81 (184)
03/2018
NOTE
: In the lower section of the above pop-
up, “
Select all
” button and “
Unselect all
”
button, respectively, select all the available Psets and unselect all the Psets (after selecting
them) at the same time.
After selecting the Psets to be deleted, “
Delete
” button (placed in the right lower corner of the
following pop-up) gets active: click on it in order to delete the selected Pset(s).
6.1
Torque Parameters
Cycle Start
Torque value from which the tightening operation starts.
This must be higher than the
min. load value
; if it is not, when the Pset
starts,
a “
Min load error
” message is shown on the display.
Angle threshold
For strategies that include the angle measurement, this parameter specifies
the torque value from which the measure of the angle starts.
Min torque
Lower torque limit.
Target torque
Torque value set by user as
tightening goal
. This parameter is available
only in the
“Production:
Torque Time
” and “Production: Torque & Angle”
strategies
.
Max torque
Higher torque limit.
Torque
correction
coefficient
For normal operations, this parameter is set to 1 (default value for
Torque
correction coefficient
).
If an extension is used, this coefficient permits to compensate the effect of
the extension on the torque measurement.
Refer to the “
Appendix A
– Calculating Correction Coefficient for Extension
”
for further details about how to calculate this coefficient.
Delete
button