8.2.1.10 Tag identifier
Tag identifier
This parameter shows the number written in the RFID TAG of the end
fitting tool. Click on the
refresh
icon on the right to refresh the parameter in
case a new end fitting tool is plugged into the Delta Wrench.
It is possible to modify the
Tag identifier
value by opening the relative drop-
down list and selecting the new one according to customer needs.
The
Tag identifier drop-down list
can range from
001
to
200
(refer to the
picture on the right).
8.2.1.11 Change screw check
Change screw check
This parameter allows enabling or disabling the warning message when
the Change screw torque is reached during the execution of a Pset. In the
case
Change screw check
is set to
Disable
, a popup message is shown
on DeltaQC that informs that the operator may damage the tightened
screw without receiving any warning:
8.2.1.12 Power off [minutes]
Power off [minutes]
This parameter allows setting the power off timeout.
The available values are:
•
Disabled: Delta Wrench does not switch off if not active
•
5-10-15-30: if not active, Delta Wrench switches off after 5-10-15-30
minutes. Delta Wrench is active in the following cases:
o
the operator is navigating in the menu items
o
a Pset or a Demo mode tightening is being executed
o
Delta Wrench is connected to DeltaQC
o
Wi-Fi connection is enabled from DeltaQC