Part Number
Issue
Date
Page
6159937790
12
03/2018
120 / 184
03/2018
120 (184)
8.2.1.13 WLAN/Open Protocol: number of results before wrench lock
WLAN/Open Protocol:
number of results before
wrench lock
This option is available only for Delta Wrench provided with a WLAN
radio module
.
When the WLAN radio module is enabled (for further details about
how to enable the WLAN radio module, refer to the chapter “
WLAN
Communication Protocol
”), the Delta Wrench can communicate with
a remote device via connection without cables.
If, during test, the Delta Wrench is out of transmission coverage, the
option “
WLAN/Open Protocol: number of resu
lts before wrench lock”
defines the number of results allowed before to completely lock the
Delta Wrench.
It is possible to set the number of results before wrench lock by
selecting among the following options:
•
0
•
50
•
100
•
250
•
500
By default, the number of results before wrench lock is equal to
500
.
NOTE
: The option “
WLAN/Open Protocol: number of
results before wrench lock”
is disabled if it is set to
0
.
NOTE
: It is necessary to disable the radio module
connection before saving the “
WLAN/Open Protocol:
wrench lock
” parameter. The radio module connection is
disabled and enabled again automatically.
Once the Delta Wrench gets out of transmission coverage during
measurement,
and the “
number of results before wrench lock
” is
reached, the following Delta Wrench display is shown:
When the Delta Wrench returns within the transmission coverage,
the above “
Wrench Locked
” screen is no longer displayed and the
measure screen is shown again.
NOTE
: If the Delta Wrench is locked (out of transmission
coverage), no one Pset can start, even if the Delta Wrench
is switched off and on again.