Part Number
Issue
Date
Page
6159937790
12
03/2018
145 / 184
145 (184)
03/2018
The
Results Viewer page
shows a group of records (organized in columns) that meet the search
criteria set by the customer.
The most important columns are summarized in the following table:
Pset number
The Pset number is defined in the Pset data.
Status
This is the global status of the test. It is
OK
when the result has
been detected according to the thresholds and limits specified, and
if the torque does not exceed the maximum transducer overload.
Torque Status
These fields indicate the result for the torque. If the result is within
the torque limits, the status is
OK
.
If the
Check Type
in the Pset parameters is set to
Angle
, the torque
status is marked as
OK
regardless the torque is inside or outside
the torque limits specified in the Pset.
If the torque goes over the maximum transducer overload the result
is marked as
HIGH
. With reference to the
Result details
field, an
overload result is marked with
the “Overload detected” message.
Angle Status
These fields indicate the result for the angle. If the result is within
the angle limits the status is
OK
.
If the
Check Type
in the Pset parameters is set to
Torque
, the angle
status is marked as
OK
regardless the angle is inside or outside the
torque limits specified in the Pset.
Result number
Progressive number automatically assigned by the Delta Wrench to
every tightening result.
Min value: 1
Max value: 1000
When 1000 results are stored in the Delta Wrench memory, the new
results overwrite the oldest starting from result number
1
.
Strategy
Type of test executed.
Torque peak
For
Residual Torque/Angle
and
Residual Torque/Angle Automatic
strategies, it indicates the maximum torque reached during the test.
Torque result
and
Angle
results
Torque and angle values measured by the Delta Wrench.
Date / Time
Fields indicating the date and time of the tightening operation. Date
and time are taken from the date and time set on the Delta Wrench.
Batch status
If the batch size is zero, the
Batch status
is always OK.
If the batch size is one or more, the
Batch status
is OK when all the
Psets of the batch are OK.
Unit of Measurement
Unit of measurement.